THE LANDING GEAR AND THE RELATED DOORS
-COMPONENTS THAT MOVE.
WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING
_______
GEAR.
1. Reason for the Job
__________________
R Do this procedure when heavy microbiological contamination is found in the R fuel tanks.
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific air blower
No specific brush
No specific container
No specific sponge
No specific warning notices
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 11-006 USA OM-232-GR-A AMS-3004 MIL-A-6090 METHYL ALCOHOL (Ref. 20-31-00) Material No. 11-009 CLEANING FOR MICROBI OLOGICAL DEBRIS (Ref. 20-31-00)
1EFF : ALL 1 28-11-00Page 301 1 1 May 01/05 1 1 1CES 1 C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R R R R R R R R 28-00-00-910-001 28-10-00-910-002 28-11-00-600-009 28-11-00-600-009 28-11-00-600-009 28-11-00-600-009 28-12-45-000-001 28-12-45-400-002 28-12-46-000-001 28-12-46-400-001 28-25-00-650-001 28-25-00-650-003
57-17-11-000-001 57-17-11-000-001
57-17-11-400-001 57-17-11-400-001
57-27-11-000-001
57-27-11-000-002
57-27-11-400-001
57-27-11-400-002
R ASRM 517000
Fuel Safety ProceduresAccess to the Fuel Tanks and the Work Areas Biocidal Shock Treatment for Heavy Contamination -With Fuel Mixed with Biobor Biocide Biocidal Shock Treatment for Heavy Contamination -With Fuel Mixed with Kathon Biocide Biocidal Shock Treatment for Heavy Contamination -Using Biobor Biocide With a Metered Injection Rig Biocidal Shock Treatment for Heavy Contamination -Using Kathon Biocide With a Metered Injection RigRemoval of the Panel Assembly 550CB(650CB)Installation of the Panel Assembly 550CB(650CB)Removal of the Overpressure-Protector OutletInstallation of the Overpressure-Protector OutletPressure DefuelTo Drain Remaining Fuel from the Wing Tanks and the Center TankRemoval of the Covers 147AZ (148AZ)Removal of the Access Cover 148AZ and the ACT-Equipment Support DoorInstallation of the Covers 147AZ (148AZ)Installation of the Access Cover 148AZ and the ACT-Equipment Support DoorRemoval of the Access Panel (540AB, 540BB, 540CB, 540DB, 540EB, 540FB, 540GB, 640AB, 640BB, 640CB, 640DB, 640EB, 640FB, 640GB)Removal of the Access Panel (540HB, 540JB, 540KB, 540LB, 540MB, 540NB, 540PB, 540QB, 540RB, 550AB, 550BB, 550CB, 550DB, 560AB, 640HB, 640JB, 640KB, ....)Installation of the Access Panel (540AB, 540BB, 540CB, 540DB, 540EB, 540FB, 540GB, 640AB, 640BB, 640CB, 640DB, 640EB, 640FB, 640GB)Installation of the Access Panel (540HB, 540JB, 540KB, 540LB, 540MB, 540NB, 540PB, 540QB, 540RB, 550AB, 550BB, 550CB, 550DB, 560AB, 640HB, 640JB, ....)
1EFF : ALL 1 28-11-00Page 302 1 1 May 01/05 1 1 1CES 1 1EFF : ALL 1 28-11-00Page 303 1 1 Aug 01/05 1 1 1CES 1 540QB, 540RB, 550AB, 550BB, 550CB, 550DB 640AB, 640BB, 640CB, 640DB, 640EB, 640FB, 640GB, 640HB, 640JB, 640KB, 640LB, 640MB 640NB, 640PB, 640QB, 640RB, 650AB, 650BB, 650CB, 650DB 147AZ, 148AZ.
3. Job Set-up__________
Subtask 28-11-00-941-076
A. Safety Precautions
WARNING : OBEY THE FUEL SAFETY PROCEDURES._______
R R R R R WARNING : ALWAYS PUT ON AN APPROVED RESPIRATOR AND PROTECTIVE CLOTHING_______ BEFORE YOU GO INTO A FUEL TANK THAT HAS MICROBIAL CONTAMINATION. IF YOU BREATHE IN OR TOUCH THE MICROBIAL GROWTH, THERE CAN BE A HEALTH RISK.
R R (1) Obey the fuel safety procedures when you do work on the fuel system (Ref. TASK 28-00-00-910-001).
(2) Put warning notices in the cockpit to tell persons not to operate: - the flap/slat system - the fuel system.
(3) Put the safety barriers in position.
Subtask 28-11-00-860-058
B. Aircraft Maintenance Configuration
(1) Defuel the aircraft (Ref. TASK 28-25-00-650-001).
(2) Drain the remaining fuel from all of the fuel tanks (Ref. TASK 28-25-00-650-003).
R **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 401-499,
Subtask 28-11-00-010-055
C. Get Access
WARNING : OBEY THE SAFETY PROCEDURES WHEN YOU DO WORK IN A FUEL TANK._______
(1) Get access to the fuel tanks (Ref. TASK 28-12-45-000-001) (Ref. TASK 28-12-46-000-001), (Ref. TASK 57-27-11-000-001), (Ref. TASK 57-27-11-000-002), (Ref. TASK 57-17-11-000-001), (Ref. TASK 28-10-00-910-002) . Remove these panels: - the wing fuel tank access panels 540AB, 540BB, 540CB, 540DB, 540EB, 540FB, 540GB, 540HB, 540JB, 540KB, 540LB, 540MB 540NB, 540PB,
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油1(81)