R Subtask 28-11-00-670-052
R B. Biocidal Shock Treatment for Moderate Contamination - using Biobor
R Biocide with a Metered Injection Rig
R CAUTION : DO NOT USE A LARGE QUANTITY OF BIOBOR BIOCIDE IN THE FUEL:_______
R - MORE THAN 270 PPM IS NOT PERMITTED IN THE ENGINES
R - MORE THAN 1000 PPM CAN CAUSE SOLIDS IF THERE IS WATER IN THE
R FUEL.
R NOTE : It is not necessary to defuel the aircraft before you start the____
R biocide treatment. AIRBUS recommends that this procedure be done
R with the minimum amount of fuel on board (after flight and before
R fuel servicing).
R (1) To refuel the aircraft with the correct proportion of Biobor and
R fuel, (270 parts per million by weight) use the formula that follows
R for each fuel tank.
R
R C(uf) = 270(FOB+UPLIFT)-FOB
R ---------------------
R UPLIFT
R
R Where:
R - C(uf) is the concentration of Biobor required in the fuel to be
R added in parts per million (ppm)
R - FOB is the fuel quantity (kg/lbs) already on board the aircraft
R (without added Biobor)
R - UPLIFT is the refuel quantity (kg/lbs) required to fill the
R aircraft (with Biobor added).
R
R For example, if the fuel quantity on board (FOB) was 10000 (kg/lbs)
R and the refuel quantity to add (UPLIFT) was 10000 (kg/lbs):
R
R C(uf) = 270(10000+10000)-10000
R ------------------------
R 10000
R
R C(uf) = 5390000
R ---------
R 10000
R
R C(uf) = 539
R
R Thus the amount of Biobor necessary in the refuel quantity (UPLIFT)
R is 539 ppm by weight.
R
R NOTE : The concentration of Biobor in the refuel quantity must not be____
R more than 1000 ppm by weight. If the result of the calculation
R is more than 1000 ppm, you must:
R - defuel the aircraft (Ref. TASK 28-25-00-650-001)
R - refuel the aircraft with the correct concentration of fuel
R and Biobor (270 ppm by weight) (Ref. TASK 12-11-28-650-003).
R (2) Record the onboard fuel quantity for each fuel tank.
R (3) Calculate the necessary quantity of fuel to be added to each fuel
R tank.
R (4) Use the procedure given in step (1) to calculate the correct
R concentration of BIOBOR to add during refuel.
R (5) Put MICROBIOLOGICAL CONTAMIN. PROTECT. MATERIALS (Material No. 17-
R 003) into the METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES
R INC.(CAGE CODE 0U7J1).
R (6) Make sure that the METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL
R ADDITIVES INC.(CAGE CODE 0U7J1) is correctly electrically bonded.
R (7) Connect the fuel tanker to the input side of a METERING EQUIPMENT -
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油1(88)