• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-22 06:45来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R  BIOCIDE, HAMMONDS FUEL ADDITIVES INC.(CAGE CODE 0U7J1). 
R  (8) Connect the output side of the METERING EQUIPMENT - BIOCIDE, HAMMONDS 
R  FUEL ADDITIVES INC.(CAGE CODE 0U7J1) to the aircraft. 
R  (9) Do a manual refuel of each fuel tank to its maximum capacity 
R  (Ref. TASK 12-11-28-650-004). Make sure that the fuel added is 
R  treated with Biobor at the correct concentration. The Biobor 
R  concentration in each tank after refuel must be 270 ppm (by weight) 
R  or less. 
R  NOTE : AIRBUS recommends that you refuel the aircraft to the maximum____ 
R  capacity. If this is not done, (for operational reasons) 
R  microbiological contamination can stay in the upper parts of 
R  the fuel tanks. 
R  (10) Disconnect the METERING EQUIPMENT - BIOCIDE, HAMMONDS FUEL ADDITIVES 
R  INC.(CAGE CODE 0U7J1) and the tanker from the aircraft.

 

R  Subtask 28-11-00-860-100 
R  C. Aircraft Maintenance Configuration 
R  (1) Do the EIS stop procedure (Ref. TASK 31-60-00-860-002). 
R  (2) De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-
R  002). 
R  Subtask 28-11-00-670-053 
R  D. Fuel System Treatment 
R  (1) Let the fuel stay in the tanks for between 36 and 72 hours. 
R  NOTE : In a high ambient temperature, the soak time must be a minimum____ 
R  of 36 hours. In a low ambient temperature, the soak time must 
R  be a minimum of 72 hours. AIRBUS recommends that you always 
R  let the fuel stay in the tanks for 72 hours. 
R  (2) During the soak time: 
R  - do not move the aircraft 
R  - do not operate the fuel pumps or APU 
R  - do not do water drain tests, a high concentration of biocide will 
R  be in the sample. 
R  (3) After the soak time, the fuel and biocide is burned through the APU 
R  and engines during normal operations. 
R  NOTE : Obey the engine manufacturers restrictions and guidelines for____ 
R  your aircraft. 
R  5. Close-up________ 
R  Subtask 28-11-00-942-109 
R  A. Removal of Equipment 
R  NOTE : For disposal of waste fuel, refer to the local regulations.____ 
R  (1) Make sure that the work area is clean and clear of tool(s) and other 
R  items. 
R  (2) Remove the warning notice(s). 
R  (3) Remove the ground support and maintenance equipment, the special and 
R  standard tools and all other items.

 

R  (4) Remove the safety barriers. 
R  Subtask 28-11-00-960-053 
R  B. Replace the Fuel Filter Elements 
R  NOTE : The fuel filter elements must be replaced again after 50 to 75____ 
R  hours of operation. 
R  (1) Replace the No. 1 and 2 engine fuel filter elements again (after 50 
R  to 75 hours operation) (Ref. TASK 73-11-10-920-001). 
R  (2) Replace the APU fuel filter element again (after 50 to 75 hours 
R  operation): 
R  - for the 131-9(A) APU (Ref. TASK 49-32-41-920-001) 
R  - for the GTCP 36-300 APU (Ref. TASK 49-32-11-610-001) 
R  - for the APS 3200 APU (Ref. TASK 49-32-11-610-002). 
R  Subtask 28-11-00-281-053 
R  C. Contamination Check 
R  (1) Do the sampling procedure again in less than 10 days (but after a 
R  minimum of 5 flights) to check for contamination (Ref. TASK 12-32-28-
R  281-003). 
R  NOTE : AIRBUS recommends that if you get a negligible result, you do____ 
R  not continue to use the biocide treatment.

 

R  TASK 28-11-00-600-008- 03 
R  Biocidal Shock Treatment for Moderate Contamination - Using Kathon Biocide With 
R  a Metered Injection Rig 
R  WARNING : PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU_______ 
R  START A TASK ON OR NEAR: 
R  - THE FLIGHT CONTROLS 
R  - THE FLIGHT CONTROL SURFACES 
R  - THE LANDING GEAR AND THE RELATED DOORS 
R  - COMPONENTS THAT MOVE. 
R  WARNING : MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING_______ 
R  GEAR. 
R  1. Reason for the Job__________________ 
R  Do this procedure not more than 10 days after a sample of fuel is taken and 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FUEL 燃油1(89)