(c)
Do this task for all bonding jumpers between rib No. 9 and rib No. 10: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48405 for bonding jumper locations.
(d)
If access is not necessary for subsequent tasks, install access panel No. 5 (AMM 28-11-11/401).
S 282-037
(6) For the area in the No. 1 fuel tank between rib No. 10 (rib at WBL 279.25) and rib No. 11 (rib at WBL 304.50), do these steps:
(a)
Remove access panel No. 6 (7208) on the left wing
(AMM 28-11-11/401).
(b)
Go into the opening for access panel No. 6 (AMM 28-10-00/201).
(c)
Do this task for all bonding jumpers between rib No. 10 and rib No. 11: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48405 for bonding jumper locations.
(d)
If access is not necessary for subsequent tasks, install access panel No. 6 (AMM 28-11-11/401).
S 282-038
(7) For the area in the No. 1 fuel tank between rib No. 11 (rib at WBL 304.50) and rib No. 12 (rib at WBL 329.75), do these steps:
(a)
Remove access panel No. 7 (7209) on the left wing
(AMM 28-11-11/401).
(b)
Go into the opening for access panel No. 7 (AMM 28-10-00/201).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-00-00
ALL ú ú 01 Page 208 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
(c)
Do this task for all bonding jumpers between rib No. 11 and rib No. 12: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48405 for bonding jumper locations.
(d)
If access is not necessary for subsequent tasks, install access panel No. 7 (AMM 28-11-11/401).
S 282-039
(8) For the area in the No. 1 fuel tank between rib No. 12 (rib at WBL 329.75) and rib No. 13 (rib at WBL 355.00), do these steps:
(a)
Remove access panel No. 8 (7210) on the left wing
(AMM 28-11-11/401).
(b)
Go into the opening for access panel No. 8 (AMM 28-10-00/201).
(c)
Do this task for all bonding jumpers between rib No. 12 and rib No. 13: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48405 for bonding jumper locations.
(d)
If access is not necessary for subsequent tasks, install access panel No. 8 (AMM 28-11-11/401).
S 282-040
(9) For the area in the No. 1 fuel tank between rib No. 13 (rib at WBL 355.00) and rib No. 14 (rib at WS 453.00), do these steps:
(a)
Remove access panel No. 9 (7211) on the left wing
(AMM 28-11-11/401).
(b)
Go into the opening for access panel No. 9 (AMM 28-10-00/201).
(c)
Do this task for all bonding jumpers between rib No. 13 and rib No. 14: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48405 for bonding jumper locations.
(d)
If access is not necessary for subsequent tasks, install access panel No. 9 (AMM 28-11-11/401).
S 282-041
(10) For the area in the No. 1 fuel tank between rib No. 14 (rib at WS 453.00) and rib No. 15 (rib at WS 479.00), do these steps:
(a)
Remove access panel No. 10 (7212) on the left wing
(AMM 28-11-11/401).
(b)
Go into the opening for access panel No. 10 (AMM 28-10-00/201).
(c)
Do this task for all bonding jumpers between rib No. 14 and rib No. 15: Inspection of the Electrical Bonding Jumpers in the Fuel System. 1) Refer to drawing 65-48405 for bonding jumper locations.
(d)
If access is not necessary for subsequent tasks, install access panel No. 10 (AMM 28-11-11/401).
EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú
28-00-00
ALL ú ú 01 Page 209 ú Jul 12/01
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A 737-300/400/500MAINTENANCE MANUAL
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 燃油 FUEL 1(9)