• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-04-02 05:47来源:蓝天飞行翻译 作者:航空
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 3. Sump Drain Assembly Installation (Tool-Operated) (Fig. 401)
________________________________
 A. Equipment
 (1)  Container - to hold fuel
 B. References
 (1)  
SWPM 20-20-00, Standard Wiring Practices Manual

 (2)  
Chapter 21, Air Conditioning


 C. Access
 (1)  
Location Zone
 215 Keel Beam


 (2)  
Access Panels
 3303 A/C Access Panel
 3403 A/C Access Panel

 

 D. Procedure
 S 434-050
 (1)  
Install two new O-rings, lightly lubricated with fuel, on the drain assembly.

 S 424-051

 (2)  
Install the drain assembly.

 (a)  
Move the drain assembly up through the hole in the drain outlet structure.

 (b)  
Put the end of the drain assembly into the upper housing.

 


 S 424-052
 CAUTION: BE CAREFUL WHEN YOU ATTACH THE DRAIN ASSEMBLY TO THE UPPER
_______ HOUSING. DAMAGE TO THE DETENT EARS WHICH LOCK THE ASSEMBLY TO THE HOUSING CAN OCCUR.
 (3)  Attach the drain assembly to the housing.
 (a)  
Turn the drain assembly until the lockpin moves freely into the slot.

 (b)  
Turn the drain assembly counterclockwise until the pin locks on the detent.


 S 434-053
 (4)  Install the retaining plate on the lower housing with four bolts and four washers.
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-11-41
 ALL  ú ú 01 Page 404 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 434-054
 (5)  
Align the applicable holes and attach the retaining plate to the drain outlet structure with two bolts and two washers.

 S 714-055

 (6)  
Open and close the sump drain to make sure it operates correctly and moves freely.


 NOTE: Some fuel drains from the open drain assembly if the tank
____ contains fuel. Catch the fuel with an applicable container.
 S 414-056
 (7)  
Close the access door for the sump drain.

 S 434-057

 (8)  
Attach the bonding jumper on the drain assembly to the airplane structure.

 S 224-058

 (9)  
Do a check of the electrical bond between the drain assembly and the airplane structure (SWPM 20-20-00).


 (a)  The resistance must not be more than 0.010 ohm.
 S 414-059
 (10) Close the access door for the air conditioning bay (Ref Chapter 21).
 TASK 28-11-41-004-008
 4. Sump Drain Assembly Removal (Rod-Actuated) (Fig. 401)
___________________________
 A. Access
 (1)  
Location Zone
 215 Keel Beam


 (2)  
Access Panels
 3303 A/C Access Panel
 3403 A/C Access Panel

 

 B. Procedure
 S 014-010
 (1)  
Open the access door for the right air conditioning bay to get access to the ground strap on the drain assembly.

 S 014-011

 (2)  
Look through the access hole in the keel beam to find the screw that attaches the ground strap to the sump drain assembly.

 S 034-012

 (3)  
Remove the screw that attaches the ground strap to the sump drain assembly.


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 28-11-41
 ALL  ú ú 01 Page 405 ú Nov 15/98
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
A
737-300/400/500MAINTENANCE MANUAL
 S 414-013
 (4)
Close the access door for the right air conditioning bay.

 S 014-014

 (5)  
Open the access door for the sump drain valve for the center tank.


 NOTE: The access door for the drain valve is between the two
____ access doors for the air conditioning bay.
 S 034-015
 (6)  
Remove the bolts and the washers that hold the retaining plate to the drain well structure.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:737-300 400 500 AMM 飞机维护手册 燃油 FUEL 1(126)