 5. Close-up
________ Subtask 38-14-48-613-050
 A. Do the servicing of the potable water system (Ref. TASK 12-15-38-613-001).
 Subtask 38-14-48-410-054
 B. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the passenger/crew door 832 or 842 (Ref. TASK 52-10-00-410-001).

 (3)
 Close the drain and overflow panel 192NB.

 (4)
 Close the access door 171AL of the service panel 2023VU.

 (5)
 In the FWD cargo-compartment, install the partition panel 131PW.

 (6)
 Set the CARGO COMPT LIGHT switch 6LU to OFF.

 (7)
 Close the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-002).

 (8)
 Remove the warning notice(s).


 (9) Remove the access platform(s). Subtask 38-14-48-862-050
 C. De-energize the ground service network (Ref. TASK 24-42-00-862-001).
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-14-48Page 414 1 1 May 01/05 1 1 1CES 1 TASK 38-14-48-000-002


 Removal of the Control Handle
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
 No specific warning notice
 No specific access platform 1.5 m (4 ft. 11 in.)
 No specific access platform 1 m (3 ft. 3 in.)
 No specific access platform 2 m (6 ft. 7 in.)
 No specific access platform 3.5 m (11 ft. 6 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
 Power 38-10-00-614-002 Depressurization of the Potable Water System 52-10-00-010-001 Opening of the Passenger/Crew Door 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
 Yellow Electric Pump 38-14-48-991-001 Fig. 401 38-14-48-991-004 Fig. 404
 3. Job Set-up
__________
 Subtask 38-14-48-861-053
 A. Energize the ground service network (Ref. TASK 24-42-00-861-001).
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-14-48Page 415 1 1 May 01/05 1 1 1CES 1 Subtask 38-14-48-010-059


 B. Get Access
 (1) Put an access platform in position in front of the applicable passenger/crew door 832 or 842.
 (2)
 Open the passenger/crew door 832 or 842 (Ref. TASK 52-10-00-010-001). Subtask 38-14-48-680-053

 C.
 Depressurize the potable water system (Ref. TASK 38-10-00-614-002). Subtask 38-14-48-010-057


 D. Get Access
 (1)
 Put an access platform in position at the drain and overflow panel 192NB.

 (2)
 Open the drain and overflow panel 192NB.

 (3)
 In the drain and overflow panel, put the warning notice to tell persons not to turn the control handle.

 (4)
 Put an access platform in position at the service panel 2023VU.

 (5)
 Open the access door 171AL of the service panel 2023VU.

 (6)
 In the service panel 2023VU, put the warning notice to tell persons not to turn the control handle.

 (7)
 Put an access platform in position at the FWD cargo-compartment door

 825.

 (8)
 Open the FWD cargo-compartment door 825 (Ref. TASK 52-30-00-860-001).

 (9)
 Set the CARGO COMPT LIGHT switch 6LU to ON.


 (10) In the FWD cargo-compartment, remove the partition panel 131PW.
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-14-48Page 416 1 1 May 01/05 1 1 1CES 1 Subtask 38-14-48-865-053


 E. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
124VU SVCE/601PP/602PP/SPLY 1PX BB01
 4. Procedure
_________
 (Ref. Fig. 401/TASK 38-14-48-991-001, 404/TASK 38-14-48-991-004) Subtask 38-14-48-020-051
 A. Removal of the Control Handle
 (1)
 Remove the nut (11), the lever (10), and at the same time hold the bolt (5) and the handle (6) outside the aircraft.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(96)