R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-14-00Page 515 1 1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
- operate the fill/drain handle - the lever of the fill/drain valve from the drain to the normal 16MA moves from the open to the position. closed position.
-
the limit switch 3MP is de-energized.
-
the motorised overflow valve 8MP closes.
-
the control light 6MP goes off.
5. Close-up
________ Subtask 38-14-00-613-052
A. Do the servicing of the potable water system (Ref. TASK 12-16-38-613-001).
Subtask 38-14-00-410-059
B. Close Access
(1)
Make sure that the work area is clean and clear of tool(s) and other items.
(2)
Install the access panel 161DW.
(3)
Close the AFT cargo-compartment door (Ref. TASK 52-30-00-860-002).
(4)
Close the access panel 171AL.
(5)
Remove the access platform(s).
(6) Remove the warning notice(s). Subtask 38-14-00-862-054
C. De-energize the ground service network
(Ref. TASK 24-42-00-862-001).
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-14-00Page 516 1 1 May 01/05 1 1 1CES 1R **ON A/C 151-199, 301-399, 401-499,
TASK 38-14-00-820-002
Adjustment of the Drain Limit Switch 3MP
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
-------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific access platform 2.0 m (6 ft. 7 in.)
No specific access platform 3.0 m (9 ft. 10 in.)
B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
12-16-38-613-001 Servicing of the Toilet System 12-24-38-680-001 Draining of the Potable Water System (with Electrical Power) 24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
__________
Subtask 38-14-00-861-058
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
R 1EFF : 151-199, 301-399, 401-499, 1 38-14-00Page 517 1 1 Aug 01/05 1 1 1CES 1 Subtask 38-14-00-010-065
B. Get Access
(1)
Put the access platform in position at the potable water-service panel 171AL.
(2)
Put the access platform in position at the AFT cargo compartment door.
(3)
Open the AFT cargo compartment door.
(4)
Remove the access panel 161DW.
(5)
Open the potable water-service panel 171AL. Subtask 38-14-00-680-057
C.
Drain the potable water system (Ref. TASK 12-24-38-680-001). Subtask 38-14-00-865-080
D.
Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU WATER SYS - QUANT IND 1MA B06 2001VU WATER SYS - DRAIN 1MP B05
4. Procedure
_________ Subtask 38-14-00-820-051
A. Adjustment of the Limit Switch 3MP
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(73)