 **ON A/C 301-399,
 Subtask 38-10-00-865-064-C
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU WATER SYS - QUANT IND 1MA B06 2000VU LAV FWD & MID - HOT WATER A 1MB F02 2000VU LAV FWD & MID - HOT WATER 10MB F03 2001VU LAVATORY AFT HOT WATER D 2MB B02 2001VU LAVATORY AFT HOT WATER L/M 9MB B03 2001VU VACUUM TOILET SYSTEM LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER M 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08 2001VU WATER SYS - DRAIN 1MP B05

R 1EFF : 151-199, 301-399, 401-499, 1 38-10-00Page 214

1 1 Aug 01/05 1 1 1CES 1

 **ON A/C ALL


 Subtask 38-10-00-670-051
 C. Sanitization of the Potable Water Tank and Distribution System
 WARNING : DO NOT GET THE WATER WITH THE DISINFECTANT SOLUTION ON YOUR
_______ SKIN OR IN YOUR EYES. DO NOT LET WATER TOUCH SURFACES OTHER THAN THE WASH BASIN (WHEN THE NOZZLE ASSY IS NOT ON THE FAUCET, THE SOLUTION FLOWS OUT HORIZONTALLY). TO DO THIS: - PUT ON PROTECTIVE CLOTHING
 -
PUT ON EYE PROTECTION OR GOGGLES

 -
PUT A GUARD AROUND THE WATER FAUCET OUTLET TO CAUSE SPRAY FROM THE SOLUTION TO FLOW INTO THE WASH BASIN (SPRAY FROM THE SOLUTION MUST NOT GO ON ADJACENT SURFACES).


 (1)
 Pressurize the potable water system (Ref. TASK 38-10-00-614-001).

 (2)
 Flush each toilet 5 times.

 (3)
 Operate the water faucet in the lavatories for three minutes.

 (4)
 Operate the water faucets in the galleys and at the coffee makers/boilers for three minutes to bleed the system.

 (5)
 Refill the potable water system until the solution flows from the POTABLE WATER OVERFLOW port (Ref. TASK 12-15-38-613-002).

 (6)
 Let the disinfectant solution stay in the system for 4 hours.


 NOTE : If 100 ppm concentration mixture is used you must let the
____ disinfectant solution stay in the system for 1 hour only.
 1EFF : ALL 1 38-10-00Page 215 1 1 May 01/05R 1 1 1CES 1


 Subtask 38-10-00-670-054

 D. Sanitization of the Potable Water Tank and Distribution System (Hydrogen Peroxide (H2O2) (Herlisil)), (H BIO T50) or (ELSIL)
 (1)
 Pressurize the potable water system (Ref. TASK 38-10-00-614-001).

 (2)
 In the Lavatories


 WARNING : DO NOT GET THE WATER WITH THE DISINFECTANT SOLUTION ON YOUR
_______ SKIN OR IN YOUR EYES. DO NOT LET WATER TOUCH SURFACES OTHER THAN THE WASH BASIN (WHEN THE NOZZLE ASSY IS NOT ON THE FAUCET, THE SOLUTION FLOWS OUT HORIZONTALLY). TO DO THIS: - PUT ON PROTECTIVE CLOTHING
 -
PUT ON EYE PROTECTION OR GOGGLES

 -
PUT A GUARD AROUND THE WATER FAUCET OUTLET TO CAUSE SPRAY FROM THE SOLUTION TO FLOW INTO THE WASH BASIN (SPRAY FROM THE SOLUTION MUST NOT GO ON ADJACENT SURFACES).


 (a)
 Set the water temperature at the water faucet to COLD. Fill the washbasin with water (approximately 3l (0.79USgal)) until it flows down the overflow vent.

 (b)
 Empty the washbasin.

 (c)
 Set the water temperature at the water faucet to HOT. Fill the washbasin with water until it flows down the overflow vent.

 (d)
 Flush the toilet 15 times


 (3)
 In the Galleys

 (a)
 Operate the water faucets in the galleys and at the coffee makers/boilers and let 5l (1.3USgal) of water to flow out of each faucet.

 (b)
 Shut all the manual shutoff valves in the galleys and lavatories first, then close the fill and drain valves.

 

 (4)
 Fill the potable water system again manually with disinfectant
 solution until it flows from the POTABLE WATER OVERFLOW port
 (Ref. TASK 12-15-38-613-002).

 

 NOTE : This is to make sure that the system is full.
____
 (5) Let the disinfectant solution stay in the system for 1 hour.
 1EFF : ALL 1 38-10-00Page 216 1 1 May 01/05R 1 1 1CES 1


 (6)
 Pressurize the potable water system (Ref. TASK 38-10-00-614-001).


 (7)
 Flush the Potable Water System

 (a)
 Open the manual shutoff valves in the galleys and lavatories,

 (b)
 Flush the potable water system, start at the rear of the cabin and stop at the front.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(22)