1EFF : ALL 1 38-00-00Page 1 1 1 May 01/04 1 1 1CES 1
POTABLE - DESCRIPTION AND OPERATION
___________________________________
1. General
_______
**ON A/C 001-049, 051-099, 101-149, 201-299,
(Ref. Fig. 001)
R **ON A/C 151-199, 301-399, 401-499,
(Ref. Fig. 001A)
**ON A/C ALL
The potable water system supplies water from the water tank through a distribution system. Potable water is supplied to water faucets in the galleys and lavatories. The system also supplies potable water to the water heaters which are located below the lavatory washbasins. The potable water system includes these subsystems:
-Water Storage (Ref. AMM 38-11-00),
-Distribution (Ref. AMM 38-12-00),
-Quantity Indicating (Ref. AMM 38-13-00),
-Water Draining (Ref. AMM 38-14-00),
-Air Supply System (Ref. AMM 38-41-00),
-Potable Water Ice Protection (Ref. AMM 30-73-00),
-Drain System Ice Protection (Ref. AMM 30-71-00).
Potable Water System - Schematic
Figure 001
R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-10-00Page 2 1 1 May 01/05 1 1 1CES 1
Potable Water System - Schematic
Figure 001A
R 1EFF : 151-199, 301-399, 401-499, 1 38-10-00Page 3 1 1 Aug 01/05 1 1 1CES 1
POTABLE - MAINTENANCE PRACTICES
_______________________________
TASK 38-10-00-670-002
Sterilization of Water Tank and Distribution System
WARNING : MAKE SURE THAT THE WATER TANK IS DEPRESSURIZED.
_______
CAUTION : POINT THE OVERFLOW DRAIN HOSE IN A CORRECT CONTAINER WHEN YOU CONNECT
_______
IT.
R
1.
Reason for the Job
__________________
Refer to the MPD TASK: 381000-01
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s)
No specific filter
No specific ground air-supply cart
No specific 1 ACCESS PLATFORM 1M (3 FT)
No specific 3 CART - DESINFECTION, WATER
No specific 1 CONTAINER 5 L(1 1/2 USGAL)
No specific 2 HOSE - VINYL
B. Consumable Materials
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
No specific indicator paper (for alkali)
Material No. 14-003E
DISINFECTANT (POTABLE WATER SYSTEM) (Ref. 20-31-00)
Material No. 14-003F
DISINFECTANT (POTABLE WATER SYSTEM) (Ref. 20-31-00)
Material No. 14-003H
DISINFECTANT (Ref. 20-31-00)
R Material No. 14-003J
R DISINFECTANT HYDROGEN PEROXIDE (Ref. 20-31-00)
R Material No. 14-003K
R DISINFECTANT (Ref. 20-31-00)
C. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
12-15-38-613-001 Fill the Potable Water Tank System (Aircraft
Electrical Power Available)
12-15-38-613-002 Fill the Potable Water Tank System (Aircraft
Electrical Power not Available)
12-24-38-680-001 Draining of the Potable Water System (with Electrical
Power)
12-24-38-680-002 Draining of the Potable Water System (without
Electrical Power)
12-31-38-660-001 Cold Weather Maintenance - Water/Waste
12-33-21-618-001 Pre-conditioning through the LP Ground Connection
24-42-00-861-001 Energize the Ground Service Network from the External
Power
25-30-00-960-001 Replacement of the Galley Water-Filter Elements (if
installed)
38-10-00-614-001 Pressurization of the Potable Water System from a
Ground Air Supply
38-12-41-000-006 Removal of the Nozzle Assembly
38-12-41-400-006 Installation of the Nozzle Assembly
3. Job Set-up__________
Subtask 38-10-00-861-051
A. Energize the ground service network (Ref. TASK 24-42-00-861-001).
Subtask 38-10-00-680-050
R B. Drain the potable water system (Ref. TASK 12-24-38-680-001).
Subtask 38-10-00-560-051
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(17)