• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 09:18来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER  45MG  A02
 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER  D  39MG  A03
 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER  E  34MG  A04
 2001VU VACUUM TOILET SYSTEM/VACUUM SYS  35MG  A06
 2001VU VACUUM TOILET SYSTEM/VACUUM GEN  33MG  A08
 2001VU WATER SYS - DRAIN  1MP  B05
 **ON A/C 301-399,
 Subtask 38-10-00-865-063-C
 F. Open, safety and tag this(these) circuit breaker(s): ------------------------------------------------------------- ------------------
PANEL  SERVICE  IDENT. LOCATION

 -------------------------------------------------------------------------------2001VU WATER SYS - QUANT IND 1MA B06 2000VU LAV FWD & MID - HOT WATER A 1MB F02 2000VU LAV FWD & MID - HOT WATER 10MB F03 2001VU LAVATORY AFT HOT WATER D 2MB B02 2001VU LAVATORY AFT HOT WATER L/M 9MB B03 2001VU VACUUM TOILET SYSTEM LAVATORY POWER A 32MG A01 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER M 45MG A02 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER D 39MG A03 2001VU VACUUM TOILET SYSTEM/LAVATORY POWER L 34MG A04 2001VU VACUUM TOILET SYSTEM/VACUUM SYS 35MG A06 2001VU VACUUM TOILET SYSTEM/VACUUM GEN 33MG A08 2001VU WATER SYS - DRAIN 1MP B05

R 1EFF : 151-199, 301-399, 401-499, 1 38-10-00Page 208

1 1 Aug 01/05 1 1 1CES 1 **ON A/C 001-049, 051-099, 101-149, 201-299,


 Subtask 38-10-00-010-052
 G. Get Access
 (1)
 Put the ACCESS PLATFORM 1M (3 FT) in position at Zone 133.

 (2)
 Put the ACCESS PLATFORM 1M (3 FT) in position at Zone 171.

 (3)
 Open the service door 171AL and the drain panel doors 133AL, 192NB.

 (4)
 Connect the HOSE - VINYL to the drain connections at the potable-water drain panels.

 

R **ON A/C 151-199, 301-399, 401-499,
 Subtask 38-10-00-010-052-A
 G. Get Access
 (1)
 Put the ACCESS PLATFORM 1M (3 FT) in position at Zone 133.

 (2)
 Put the ACCESS PLATFORM 1M (3 FT) in position at Zone 171.

 (3)
 Open the service door 171AL and the drain panel door 133AL.

 (4)
 Connect the HOSE - VINYL to the drain connection at the potable-water drain panel.


 **ON A/C ALL
 Subtask 38-10-00-860-050
 H. Aircraft Maintenance Configuration WARNING : MAKE SURE THAT THE EQUIPMENT YOU USE FOR THIS PROCEDURE IS
_______ CLEAN AND APPROVED FOR THE POTABLE WATER SYSTEM. IF NOT IT CAN CAUSE CONTAMINATION OF THE POTABLE WATER SYSTEM.
 (1)
 Make sure that all the shutoff valves in the lavatories and galleys are open.

 (2)
 Make sure that the switch on each water heater is set to the OFF position.

 (3)
 Make sure that the water faucets in the lavatories and the galleys are in the middle (mixed) position.

 (4)
 Remove the water-faucet nozzle assys in the lavatories (Ref. TASK 38-12-41-000-006) and do not install them at this time.

 


 NOTE : You do not have to remove the nozzles of the water faucets
____ when (Hydrogen Peroxide (H2O2) (Herlisil)) or (H BIO T50) is used.
 (5)
 Connect the HOSE - VINYL to the waste-water drain-masts.

 (6)
 Connect the CART - DESINFECTION, WATER to the fill/drain port of the potable-water service panel.

 (7)
 Connect the ground air-supply cart to the ground air connection on the potable-water service panel.


 Subtask 38-10-00-560-052
 J. Preparation of the Water Filters
 (1)
 Remove the caps and the filter elements from the galley filter housings but do not install new elements at this time (Ref. TASK 25-30-00-960-001).

 (2)
 Install the caps on the galley filter housings and tighten the clamps.


 Subtask 38-10-00-941-056
 K. Safety Precautions
 (1) Put the warning notices in position to tell persons not to use the potable water system.
 1EFF : ALL 1 38-10-00Page 210 1 1 May 01/05R 1 1 1CES 1


 4. Procedure
_________
 **ON A/C 001-049, 051-099, 101-149, 201-299,

 Subtask 38-10-00-670-052
 A. Sanitization of the Potable Water Tank and the Distribution System
 (1) Fill the potable water system with the solution. NOTE : You must fill the potable water system without electrical
____ power. this makes sure that the tank is full and that the solution flows from the potable water overflow port.
 (a)
 On the potable water-service panel turn and pull the FILL/DRAIN handle from the NORMAL to the FILL position.

 (b)
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(20)