• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 09:18来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 (2) Open the potable water service-panel door 161AL.
 Subtask 38-13-00-680-050

 D. If necessary, drain the potable water system (Ref. TASK 12-24-38-680-001).
 NOTE : The potable water system must be empty for the subsequent test.
____
 _________

4. Procedure

R **ON A/C 001-049, 051-099, 101-149, 201-299,
 Subtask 38-13-00-710-051
 A. Operational Test of the Water Service-Panel Door-Switch 5MA
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the potable-water service panel: - turn the cable control handle 3254MM to the FILL position and pull it out.  At the potable-water service panel:- the FWD DRAIN VALVE OPEN light isoff.- the OVERFLOW VALVE OPEN light comes
 on.
 - the TANK DRAIN VALVE OPEN light is off.
 - the TANK FULL light is off.
 - turn the cable control handle 3254MM to the NORMAL position and pull it out.  - the FWD DRAIN VALVE OPEN light isoff.- the OVERFLOW VALVE OPEN light goes off.
 - the TANK DRAIN VALVE OPEN light is off.
 - the TANK FULL light is off.

 

 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-
turn the cable control handle 3254MM to the DRAIN position and pull it out.

-
turn the cable control handle 3254MM to the NORMAL position.


2. At the potable-water service panel:
-close the potable-water service-panel door 161AL.
At the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
 -push and hold the membrane switch IND ON.
 At the potable water service panel: - open the potable-water
 service-panel door 161AL.
-
the FWD DRAIN VALVE OPEN light comeson.

-
the OVERFLOW VALVE OPEN light comes on.

 -
the TANK DRAIN VALVE OPEN light comes on.

 -
the TANK FULL light is off

-
the FWD DRAIN VALVE OPEN light goesoff.

 -
the OVERFLOW VALVE OPEN light goes off.

 -
the TANK DRAIN VALVE OPEN light goes off.

 -
the TANK FULL light is off.


On the Forward Attendants Panel (FAP)120RH/miscellaneous panel WATER ANDWASTE 124RH:
-there is no indication.
-
the FAP gives an indication.

-
the FAP gives an indication.


R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-13-00Page 510 1 1 May 01/05 1 1 1CES 1

 

R **ON A/C 151-199, 301-399, 401-499,

 Subtask 38-13-00-710-051-A
 A. Operational Test of the Water Service-Panel Door-Switch 5MA
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the potable-water service panel:
 -
turn the cable control handle 3254MM to the FILL position and pull it out.

-
turn the cable control handle 3254MM to the NORMAL position.

-
turn the cable control handle 3254MM to the DRAIN position and pull it out.

-
turn the cable control handle 3254MM to the NORMAL position.


2. At the potable-water service panel:
-close the potable-water
service-panel door 161AL.

 - open the potable-water
service-panel door 161AL.

At the potable-water service panel:
-
the FWD DRAIN VALVE OPEN light isoff.

-
the TANK FULL light is off.

-
the FWD DRAIN VALVE OPEN light isoff.

 -
the TANK FULL light is off.

-
the FWD DRAIN VALVE OPEN light comeson.

-
the TANK FULL light is off

-
the FWD DRAIN VALVE OPEN light goesoff.

 -
the TANK FULL light is off.


At the Forward Attendants Panel (FAP)120RH/miscellaneous panel WATER AND WASTE 124RH:
-there is no indication.
-the FAP gives an indication.
R 1EFF : 151-199, 301-399, 401-499, 1 38-13-00Page 511 1 1 Aug 01/05 1 1 1CES 1R **ON A/C ALL

 

 5. Close-up
________
 Subtask 38-13-00-410-051

 A. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Close the potable-water service-panel door 161AL. NOTE : Make sure that the latches are correctly locked and that the


____ door makes a continuous surface with the skin of the aircraft.
 (3) Remove the access platform(s).
 Subtask 38-13-00-862-051

 B. De-energize the ground service network the aircraft electrical circuits (Ref. TASK 24-42-00-862-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(58)