 1EFF : ALL 1 38-13-16Page 405 1 1 May 01/04R 1 1 1CES 1

 3. Job Set-up
__________

 Subtask 38-13-16-860-050
 A. Aircraft Maintanance Configuration
 (1)
 Make sure that the electrical circuits are energized (Ref. TASK 24-41-00-861-002):

 (2)
 Make sure that the AFT cargo-compartment door is open and safetied (Ref. TASK 52-30-00-860-001).

 (3)
 Make sure that the CARGO COMPT light switch is set to the ON position.

 (4)
 Make sure that the access panel 161DW is removed.

 (5)
 Make sure that the access platform is in position under the potable water service-panel.

 (6)
 Make sure that the door of the potable water service-panel 171AL is open.

 (7)
 Make sure that the warning notice is in position to tell porsons that the quantity indication system will not operate.


 **ON A/C 001-049, 051-099, 101-149, 201-299,
 Subtask 38-13-16-865-053
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and
 tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2000VU WATER SYS - QUANT IND 1MA B01

R **ON A/C 151-199, 401-499,
 Subtask 38-13-16-865-053-A
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged


 -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU WATER SYS 1MA B06 
R  **ON A/C 301-399, 
R  Subtask 38-13-16-865-053-B 
R R R R R R  B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU WATER SYS - QUANT IND 1MA B06
 **ON A/C ALL
 4. Procedure_________
 (Ref. Fig. 401/TASK 38-13-16-991-001)
 Subtask 38-13-16-420-050
 A. Installation of the Water Service-Panel Door-Switch 5MA
 (1) Clean the component interface and/or the adjacent area.
 (2) Do an inspection of the component interface and/or the adjacent area.
 (3) Put the limit switch (2) in position.
 (4) Install the nut (4) and the washer (3).
 (5) Safety the nut (4) with corrosion-resistant steel lockwire 0.5 mm (0.020 in.) dia.
 (6) Remove the blanking caps from the electrical connectors.
 (7) Make sure that the electrical connectors are clean and in the correct condition.
 (8) Connect the electrical connector 6MA-A (1).

 

 **ON A/C 001-049, 051-099, 101-149, 201-299,
 Subtask 38-13-16-865-054
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2000VU WATER SYS - QUANT IND 1MA B01

R **ON A/C 151-199, 401-499,
 Subtask 38-13-16-865-054-A
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU WATER SYS 1MA B06
 **ON A/C 301-399,
 Subtask 38-13-16-865-054-B
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU WATER SYS - QUANT IND 1MA B06
 **ON A/C ALL
 Subtask 38-13-16-710-050
 C. Do an operational test of the water service-panel door-switch (Ref. TASK 38-13-00-710-002).


 5. Close-up
________ Subtask 38-13-16-410-050
 A. Close Access
 (1)
 Install the access panels 161DW.

 (2)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (3)
 Close the door of the potable water service-panel 171AL. NOTE : Make sure that the latches are correctly locked and that the

____ door makes a continuous surface with the skin of the aircraft.

 (4)
 Set the CARGO COMPT light-switch 8LU on the service panel 2024VU to the OFF position.
 