 D. Rinse Valve The toilet rinse valve is solenoid controlled and is electrically operated. (Ref. AMM 38-31-00).


 Water Heater - Electrical Schematic
 Figure 003

R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-12-00Page 8 1 1 May 01/05 1 1 1CES 1


 Water Heater - Electrical Schematic
 Figure 003A

R 1EFF : 151-199, 301-399, 401-499, 1 38-12-00Page 9 1 1 Aug 01/05 1 1 1CES 1


 DISTRIBUTION - MAINTENANCE PRACTICES
____________________________________
 TASK 38-12-00-820-001
 Adjustment of the Water-Flow Time of the Water Faucet
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific 1 SCREWDRIVER - FLAT HEAD
 No specific 1 SCREWDRIVER - SMALL
 No specific 1 STOPWATCH
 No specific 1 WRENCH - HEXAGONAL

 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from the External Power 38-10-00-614-001 Pressurization of the Potable Water System from a Ground Air Supply 38-10-00-614-002 Depressurization of the Potable Water System
 **ON A/C 001-003, 051-052,
 38-12-00-991-001 Fig. 201
R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 38-12-00-991-001-A Fig. 201A **ON A/C ALL


 3. Job Set-up
__________
 Subtask 38-12-00-861-054
 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001).

 Subtask 38-12-00-010-055
 B. Get Access
 (1)
 Open the applicable lavatory door.

 (2)
 Make sure that the potable water shutoff valve in the lavatory is open.


 **ON A/C 001-049, 051-099, 101-105,
 Subtask 38-12-00-865-057
 C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU WATER SYS - QUANT IND 1MA B01 2000VU LAV FWD - HOT WATER 1MB F02 2001VU LAVATORY AFT HOT WATER 2MB B02 2001VU LAVATORY AFT HOT WATER 9MB B03
 **ON A/C 106-149, 201-299,
 Subtask 38-12-00-865-057-B
 C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2000VU WATER SYS - QUANT IND 1MA B01 2000VU LAV FWD - HOT WATER A 1MB F02 2001VU LAVATORY AFT HOT WATER D 2MB B02 2001VU LAVATORY AFT HOT WATER E 9MB B03
 1EFF : ALL 1 38-12-00Page 202 1 1 Aug 01/05R 1 1 1CES 1

 

R **ON A/C 151-199, 401-499,
 Subtask 38-12-00-865-057-A
 C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU WATER SYS - QUANT IND 1MA B06 2000VU LAV FWD - HOT WATER 1MB F02 2001VU LAVATORY AFT HOT WATER D 2MB B02 2001VU LAVATORY AFT HOT WATER E 9MB B03
 **ON A/C 301-399,
 Subtask 38-12-00-865-057-C
 C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------2001VU WATER SYS - QUANT IND 1MA B06 2000VU LAV FWD & MID - HOT WATER 1MB F02 2000VU LAV FWD & MID - HOT WATER 10MB F03 2001VU LAVATORY AFT HOT WATER 2MB B02 2001VU LAVATORY AFT HOT WATER 9MB B03
 **ON A/C ALL
 Subtask 38-12-00-614-052
 D. Pressurize the potable water system (Ref. TASK 38-10-00-614-001).
 4. Procedure
_________
 **ON A/C 001-003, 051-052,
 (Ref. Fig. 201/TASK 38-12-00-991-001)
R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 (Ref. Fig. 201A/TASK 38-12-00-991-001-A)


 Water-Flow Time Adjustment
 Figure 201/TASK 38-12-00-991-001
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(37)