The potable Water is kept in the 3 001-049, 051-099 storage system. 101-149, 201-299 Potable Water is kept in the 6 151-199, 301-399 water storage system. 401-499,
Component Description 8 ALL
Water Tank 3000MM 8 001-049, 051-099 101-149, 201-299 Fill/Drain Valve 16MA 8 001-049, 051-099 101-149, 201-299 Water Tank 3000MM 8 151-199, 301-399
401-499, Fill/Overflow Drain Valve 8MA 9 151-199, 301-399 401-499, Overflow Valve 8MP 9 001-049, 051-099 101-149, 201-299
Operation 9 ALL Fill System (with Electrical 9 001-049, 051-099 Power) 101-149, 201-299 Fill System (with Electrical 11 151-199, 301-399 Power) 401-499,
Operation 11 001-049, 051-099
38-CONTENTS Page 1 Aug 01/05 R CES
CHAPTER 38
__________
WATER/WASTE
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY________ C ____ ___________
101-149, 201-299 Fill System (without Electrical 11 001-049, 051-099 Power) 101-149, 201-299 Drain System 11 ALL
TANK - WATER 38-11-41
REMOVAL/INSTALLATION 401 ALL
Removal of the Potable Water Tank 401 ALL
3000MM
Installation of the Potable Water 415 ALL
Tank 3000MM
TANK - WATER 38-11-41 INSPECTION/CHECK 601 001-049, 051-099
101-149, 201-299 General Visual Inspection of the 601 001-049, 051-099 Potable Water Tank 101-149, 201-299
DISTRIBUTION 38-12-00
DESCRIPTION AND OPERATION 1 ALL
General 1 ALL
System Description 1 ALL
Distribution 1 ALL
Component Description 1 ALL Water Faucet 1 ALL Manual Shut-off Valve 5 001-003, 051-052 Manual Shut-off Valve 5 004-049, 053-099
101-149, 151-199 201-299, 301-399 401-499,
Water Heater 7 ALL Rinse Valve 7 ALL
DISTRIBUTION 38-12-00
MAINTENANCE PRACTICES 201 ALL
Adjustment of the Water-Flow Time 201 ALL
of the Water Faucet
DISTRIBUTION 38-12-00
ADJUSTMENT/TEST 501 ALL
Operational Test of the Potable 501 ALL
Water-Distribution System (with
the APU)
Operational Test of the Potable 503 ALL
Water-Distribution System (with a
Ground Air-Supply Cart)
38-CONTENTS Page 2 Aug 01/05 R CES
CHAPTER 38
__________
WATER/WASTE
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ Operational Test of a Potable 507 ALL Water Heater
VALVE - POTABLE WATER 38-12-14
REMOVAL/INSTALLATION 401 ALL Removal of a Potable Water-Shutoff 401 ALL Valve Installation of a Potable 408 ALL Water-Shutoff Valve
WATER HEATER 38-12-16
REMOVAL/INSTALLATION 401 ALL Removal of the Water Heater 401 ALL Installation of the Water Heater 407 ALL
FAUCET - WASH BASIN 38-12-41
REMOVAL/INSTALLATION 401 ALL Removal of the Water Faucet 401 ALL Installation of the Water Faucet 407 ALL Removal of the Selfclosing -412 ALL Element Installation of the Selfclosing -417 ALL Element Removal of the Nozzle Assembly 422 ALL Installation of the Nozzle 427 ALL Assembly
QUANTITY INDICATING 38-13-00
DESCRIPTION AND OPERATION 1 ALL General 1 ALL Component Location 1 ALL Description 4 ALL Water Quantity Transmitter 3MA 4 ALL Service Door 171AL 4 ALL Light Emitting Diode (LED) 4 ALL Circuit Breaker 1MA 4 ALL Indicator Light 10MA 4 ALL System Operation 4 ALL
QUANTITY INDICATING 38-13-00
MAINTENANCE PRACTICES 201 ALL
Indication Lamps Replacement 201 ALL
QUANTITY INDICATING 38-13-00
ADJUSTMENT/TEST 501 ALL Operational Test of the Quantity 501 ALL Indicating System
38-CONTENTS Page 3 Aug 01/05 R CES
CHAPTER 38
__________
WATER/WASTE
TABLE OF CONTENTS
_________________
SUBJECT_______ CH/SE/SU _ PAGE EFFECTIVITY
________ C ____ ___________ Operational Test of the Door Limit 508 ALL Switch 5MA
TRANSMITTER QUANTITY 38-13-11
REMOVAL/INSTALLATION 401 ALL
Removal of the Quantity 401 ALL
Transmitter 3MA
Installation of the Quantity 408 ALL
Transmitter 3MA
LIMIT SWITCH - WATER SERVICE PANEL 38-13-16
DOOR
REMOVAL/INSTALLATION 401 ALL
Removal of the Water Service-Panel 401 ALL
Door-Switch (5MA)
Installation of the Water 405 ALL
Service-Panel Door-Switch (5MA)
INDICATOR QUANTITY 38-13-21
REMOVAL/INSTALLATION 401 ALL
Removal of the Quantity Indicator 401 ALL
6MA
Installation of the Quantity 405 ALL
中国航空网 www.aero.cn