• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-26 09:18来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

R **ON A/C 151-199, 301-399, 401-499,
 (Ref. Fig. 401A/TASK 38-14-47-991-001-A) **ON A/C ALL


 WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK
_______ AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.
 WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE THIS/THESE
_______ MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES AND GOGGLES.
 (1)
 Remove the sealant from the service panel with a nonmetallic scraper.

 (2)
 Clean the service panel with CLEANING AGENTS (Material No. 11-003).

 (3)
 Clean the cable (3) with CLEANING AGENTS (Material No. 11-002).

 (4)
 Do an inspection of the component interface and/or the adjacent area.

 (5)
 Apply COMMON GREASE (Material No. 04-004) to the cable (3).


 Subtask 38-14-47-420-050
 B. Installation of the Control Cable
 **ON A/C 001-049, 051-099, 101-149, 201-299,
 (Ref. Fig. 401/TASK 38-14-47-991-001)
R **ON A/C 151-199, 301-399, 401-499,
 (Ref. Fig. 401A/TASK 38-14-47-991-001-A)

 **ON A/C ALL


 (1)
 Put the swivel end (6) in position.

 (2)
 Install the washer (5) and the nut (4).

 (3)
 Put the casing (2) in position.

 (4)
 Install the nut (1) in the swivel end (6) but do not tighten at this time.


 WARNING : MAKE SURE THAT THERE IS A GOOD FLOW OF AIR THROUGH THE WORK
_______ AREA WHEN YOU USE SPECIAL MATERIALS. IF YOU GET ONE OF THESE MATERIALS ON YOUR SKIN, IN YOUR MOUTH OR IN YOUR EYES : -FLUSH IT AWAY WITH A FLOW OF CLEAN WATER FOR BETWEEN 10 AND 15 MINUTES. -GET IMMEDIATE MEDICAL AID IF IRRITATION OCCURS. DO NOT BREATHE THE FUMES FROM THE MATERIAL. DO NOT SMOKE WHEN YOU USE THE MATERIAL. DO NOT USE THE MATERIAL NEAR A FLAME, SPARKS OR SOURCES OF HEAT. THESE MATERIALS ARE DANGEROUS : THEY ARE POISONOUS, FLAMMABLE AND SKIN IRRITANTS.

R WARNING : OBEY THE MANUFACTURER'S INSTRUCTIONS WHEN YOU USE
_______ R THIS/THESE MATERIAL/S. USE PROTECTIVE CLOTHING, RUBBER GLOVES AND GOGGLES.
 (a)
 Apply SPECIAL MATERIALS (Material No. 05-013) to the flange of the handle (12).

 (b)
 Apply SEALANTS (Material No. 09-019) to the flange of the control handle assembly (12) and to the screws (13).

 (c)
 Install the cable (3) in the casing (2).

 (d)
 Put the control handle assembly (12) in position.

 (e)
 Install the screws (13) the washers (14) and the nuts (15).

 (f)
 Install the nut (1) in the handle (12).

 (g)
 Tighten the nuts (1).

 (h)
 Install the sliding end (11) on the cable (3).

 

 

R **ON A/C 001-049, 051-099, 101-149, 201-299,

 Subtask 38-14-47-820-050
 C. Adjustment of the Control Cable (Ref. Fig. 401/TASK 38-14-47-991-001)
 (1)
 Make sure that the fill/drain handle is in the normal position.

 (2)
 Hold the lever of the fill/drain valve 16MA in the closed position.

 (3)
 Adjust the sliding end (11) until you can install the pin (7). NOTE : The sliding end (11) is left hand threaded.

____

 (4)
 Make sure that you can feel or see the cable (3) through the inspection hole in the sliding end (11).

 (5)
 Install the pin (7) the washer (8) and the new cotter pin (9).


 (6) Tighten the nut (10). Subtask 38-14-47-865-056
 D. Remove the safety clip(s) and the tag(s) and close this(these) circuit
 breaker(s): -------------------------------------------------------------------------------
PANEL ------ SERVICE --------------------------------- --------------------- IDENT. LOCATION-------------------
2000VU WATER SYS - QUANT IND  1MA  B01
 Subtask 38-14-47-720-050
 E. Do this test.
 ---------------------------------------ACTION  ---------------------RESULT -------------------

-------------------------------------------------------------------------------
1. At the service panel 2023VU: In the potable water system:
 - operate the fill/drain handle  - the lever of the fill/drain valve from the normal to the drain 16MA moves from the closed to the position. open position.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(91)