R 1EFF : ALL 1 38-11-41Page 420 1 1 Aug 01/05 1 1 1CES 1
R (b) Install the pin (26) the washer (25) and a new cotter pin (24).
NOTE : Make sure that you do not dent or cause damage to the____
tank. Dents or damage to the tank could cause a leak to
occur.
R
R (c) Remove the blanking plugs.
R
R (d) Put the overflow line (7) in position.
R
R (e) Move the sleeve (5) in position over the O-rings (4) and install
R the clamshell (6).
R
R (f) Connect the air-pressure line (8).
R
R (g) Put the distribution line assembly (16) in position.
R
R (h) Move the sleeve (17) in position over the O-rings (15) and
R install the clamshell (18).
R
R (i) Tighten the two tank attach clamps (9) and TORQUE to 0.6 m.daN
(53.09 lbf.in).
R (5) Connect the Electrical Connector
R
R (a) Remove the blanking caps.
R
R (b) Make sure that the electrical connectors are clean and in the
R correct condition.
R
R (c) Connect the electrical connector 3 MA-A to the quantity
R transmitter 3MA
R 1EFF : 151-199, 301-399, 401-499, 1 38-11-41Page 421 1 1 Aug 01/05 1 1 1CES 1
**ON A/C ALL
Subtask 38-11-41-860-050
B. Preparation for Test
(1)
Remove the warning notice(s).
(2)
Make sure that the potable water air system does not leak (Ref. TASK 38-41-00-790-002).
(3)
Fill the potable water system (Ref. TASK 12-15-38-613-001).
(4) Pressurize the potable water system (Ref. TASK 38-10-00-614-001). Subtask 38-11-41-710-051
C. Test
(1) Do this test
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. In the lavatory/galley In the lavatory/galley - operate the water faucet. - water flows from the water faucet.
(2) If necessary do the test of the quantity indicating system (Ref. TASK 38-13-00-710-001).
(3) Make sure that there are no leaks. Subtask 38-11-41-670-050
D. Do the sterilization of the potable water system (Ref. TASK 38-10-00-670-002).
1EFF : ALL 1 38-11-41Page 422 1 1 Aug 01/05R 1 1 1CES 1
5. Close-up
________
**ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 38-11-41-410-051
A. Close Access
(1) Install the air conditioning ducts.
(Ref. Fig. 402/TASK 38-11-41-991-007)
(a) Install the rear duct (40).
Detail B and H.
1 Put the duct (40) in position.
_
2 Install the bellows (44) and (66).
_
3 Install the clamps (43) and (63).
_
4 Make sure that the bellows are located between the red marks.
_
5 Install the clamp (64) and make sure that it is fully around
_
the bracket (65).
(b) Install the bracket assembly (62).
Detail J.
1 Put the bracket assembly (62) in position.
_
2 Install the washers (60) and the bolts (61).
_
R 3_ If removed, install the clamps of the cable bundle aft of theR bracket assembly.
(c) Install the bend duct (42).
Detail D, E, F and G.
1 Put the bend duct (42) in position.
_
2 Install the bellows (53) and (55).
_
3 Install the clamps (50) and (52).
_
4 Make sure that the bellows are located between the red marks.
_
R 1EFF : ALL 1 38-11-41Page 423 1 1 Aug 01/05 1 1 1CES 1 5 Install the clamp (54) and make sure that it is fully around
_
the bracket (51).
(d) Install the fwd duct (41).
Detail B and C.
1 Put the duct (41) in position.
_
2 Install the bellows (44).
_
3 Install the clamps (43) and (45).
_
4 Make sure that the bellows are between the red marks.
_
(2)
Install the recirculation filter 4012HM (Ref. TASK 21-21-41-400-001). (Ref. Fig. 401/TASK 38-11-41-991-008)
(3)
Installation of the access panels-support struts (31) and (34). WARNING : USE SOLVENTS/CLEANING AGENTS, SEALANTS AND OTHER SPECIAL