R 1EFF : 001-003, 051-052, 1 38-12-00Page 204 1 1 May 01/05 1 1 1CES 1


 Water-Flow Time Adjustment
 Figure 201A/TASK 38-12-00-991-001-A

R 1EFF : 004-049, 053-099, 101-149, 151-199, 1 38-12-00Page 205 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1

 

R **ON A/C 001-003, 051-052,

 Subtask 38-12-00-820-050
 A. Adjustment of the Water-Faucet Flow Time
 NOTE : Make sure that the water nozzle is clean and not calcified before
____
 you do this task|

 NOTE : The manufacturer has pre-adjusted the flow time of the
____
 water-faucet to 10 +2-2 s.

 Table 1 - Water-Faucet Data Setting -------------------------------------------------------------------------------I System Press I Normal Operating I Duration of I Flow Rate I I I Press I Water Flow I I --------------------I----------------------I----------------I-----------------I I Between I Between I Between I I I 0 and 2.07 bar I 1.52 and 1.87 bar I 3 and 18 s I 2l/min I I(0 and 30 psi) I (22 and 27 psi) I I(0.53 USgal/min) I -------------------------------------------------------------------------------
(1)
 Set the water-faucet temperature control to the central position before you adjust the water-faucet flow time.

 (2)
 Remove the placard (1) from the lever cap assembly (4).

 (3)
 Put a SCREWDRIVER - SMALL through the hole into the self-closing element (3) until it engages in the slot of the regulating needle (2).

 (4)
 Use the screwdriver to turn the regulating needle (2) clockwise until it stops.


 NOTE : Do not use to much force when you do the above step.
____
 (5)
 Push the water faucet:

 -no water will flow.

 (6)
 Turn the regulating needle (2) slowly counterclockwise to increase the flow time.

 (7)
 Push the water-faucet and measure the flow time.


 NOTE : The water pressure and temperature effect the flow time of the
____ water faucet; the colder the water, the longer the flow time.
R 1EFF : 001-003, 051-052, 1 38-12-00Page 206 1 1 May 01/05 1 1 1CES 1


 (8)
 Adjust the regulating needle again until the necessary flow time is reached.

 (9)
 Put the lever cap assembly (4) in the middle position and install the placard (1). Make sure that the red mark (warm) is on the left and the blue mark (cold) is on the right.


 (10) Make sure that the cap assembly (4) is in the middle position between the COLD and HOT range.

R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
 Subtask 38-12-00-820-050-A
 A. Adjustment of the Water-Faucet Flow Time
 NOTE : Make sure that the water nozzle is clean and not calcified before
____
 you do this task|

 NOTE : The manufacturer has pre-adjusted the flow time of the
____
 water-faucet to 10 +2-2 s.

 Table 1 - Water-Faucet Data Setting -------------------------------------------------------------------------------I System Press I Normal Operating I Duration of I Flow Rate I I I Press I Water Flow I I --------------------I----------------------I----------------I-----------------I I Between I Between I Between I I I 1.24 and 2.02 bar I 1.72 and 1.93 bar I 3 and 16 s I 2l/min I I (18 and 30 psi) I (25 and 28 psi) I I(0.53 USgal/min) I -------------------------------------------------------------------------------
(1)
 Set the water-faucet temperature control to the central position before you adjust the water-faucet flow time.

 (2)
 Remove the knob (3)

 (a)
 Remove the cove (1).

 (b)
 Use a WRENCH - HEXAGONAL and loosen the screw (2).

 

 (3)
 Use a SCREWDRIVER - FLAT HEAD and adjust the water-flow time as follows:

 (4)
 Turn the adjusting screw in the water faucet (4) clockwise to decrease the flow time.

 (5)
 Turn the adjusting screw counterclockwise to increase the flow time.


 (6)
 Operate the water faucet (4).

 (7)
 Use a STOPWATCH and make sure that the water flows for between 10 and 18 seconds.

 


 NOTE : The water pressure and the temperature effect the flow time of
____ the water faucet; the colder the water, the longer the flow
 time. R The maximum flow time of the water should not be more than 16 R seconds.
 (8)
 Do the procedure again if the flow time is not satisfactorily.

 (9)
 Put the knob (3) in position and tighten the screw (2).


 (10) Install the cover (1).
 **ON A/C ALL
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM WATER/WASTE 1(38)