B. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External Power 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 38-13-16-991-001 Fig. 401
3. Job Set-up
__________
Subtask 38-13-16-861-050
A. Energize the ground service network
(Ref. TASK 24-42-00-861-001).
**ON A/C 001-049, 051-099, 101-149, 201-299,
Subtask 38-13-16-865-050
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2000VU WATER SYS - QUANT IND 1MA B01
R **ON A/C 151-199, 401-499,
Subtask 38-13-16-865-050-A
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU WATER SYS 1MA B06
**ON A/C 301-399,
Subtask 38-13-16-865-050-B
B. Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------
2001VU WATER SYS - QUANT IND 1MA B06
**ON A/C ALL
Subtask 38-13-16-010-051
C. Get Access
(1)
Open and safety the AFT cargo-compartment door (Ref. TASK 52-30-00-860-001).
(2)
Set the CARGO COMPT light-switch 8LU on the service panel 2024VU to the ON position.
(3)
Remove the access panel 161DW.
(4)
Put an access platform in position below the potable water service-panel.
(5)
Open the potable-water service-panel door 171AL.
(6)
Put the warning notice in position to tell persons that the quantity indication system will not operate.
4. Procedure
_________
(Ref. Fig. 401/TASK 38-13-16-991-001) Subtask 38-13-16-020-050
A. Removal of the Water Service-Panel Door-Switch 5MA
(1)
Disconnect the electrical connector 5MA-A (1).
(2)
Put blanking caps on the disconnected electrical connectors.
(3)
Remove and discard the lockwire from the nut (4).
(4)
Remove the nut (4) and the washer (3).
(5)
Remove the switch (2).
1EFF : ALL 1 38-13-16Page 403 1 1 May 01/04R 1 1 1CES 1
Water Service-Panel Door-Switch (5MA) Figure 401/TASK 38-13-16-991-001
1EFF : 1 1R 1CES ALL 1 11 1 38-13-16 Page 404 May 01/04
TASK 38-13-16-400-001
Installation of the Water Service-Panel Door-Switch (5MA)
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific warning notice
B. Consumable Materials
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
No specific corrosion-resistant steel lockwire 0.5 mm (0.020 in.) dia.
C. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-42-00-862-001 De-energize the Ground Service Network Supplied from
the External Power 38-13-00-710-002 Operational Test of the Door Limit Switch 5MA 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the
Yellow Electric Pump 52-30-00-860-002 Close the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 38-13-16-991-001 Fig. 401