R  (7) Remove the access platform(s). 
R  (8) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
 Subtask 38-14-17-862-050
 B. De-energize the ground service network (Ref. TASK 24-42-00-862-001).

 

 LIMIT SWITCH - FILL CONDITION (5MP) - REMOVAL/INSTALLATION
__________________________________________________________ TASK 38-14-19-000-001 Removal of the Fill - Condition Limit - Switch (5MP) NOTE : The Fill-Condition Limit-Switch 5MP is refered to in the subsequent
____ procedure as the Limit Switch 5MP.
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
 No specific circuit breaker(s) safety clip(s)
 No specific 1 ACCESS PLATFORM 2M (6 FT)
 No specific 1 ACCESS PLATFORM 3M (10 FT)

 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001  Energize the Ground Service Network from the External Power 52-30-00-860-001 Open the FWD or AFT Cargo-Compartment Door with the Yellow Electric Pump 38-14-19-991-001 Fig. 401
 3. Job Set-up
__________ Subtask 38-14-19-861-050
 A. Energize the ground service network
 (Ref. TASK 24-42-00-861-001)

R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-14-19Page 401 1 1 May 01/05 1 1 1CES 1


 Subtask 38-14-19-010-050

 B. Get Access
 (1)
 Put the ACCESS PLATFORM 3M (10 FT) in position at the access door 171AL of the potable water-service panel.

 (2)
 Open the AFT cargo compartment door (Ref. TASK 52-30-00-860-001).

 (3)
 Put the ACCESS PLATFORM 2M (6 FT) in position at the AFT cargo compartment door.

 (4)
 In the AFT cargo compartment, on the control panel 5024VE set the light switch 30LU to the ON position.

 (5)
 Remove the access panel 161DW.


 (6)
 Open the access door 171AL. Subtask 38-14-19-865-050

 C.
 Open, safety and tag this(these) circuit breaker(s): -------------------------------------------------------------------------------PANEL SERVICE IDENT. LOCATION -------------------------------------------------------------------------------


2000VU WATER SYS - QUANT IND 1MA B01 2001VU WATER SYS - DRAIN 1MP B05
 4. Procedure
_________ Subtask 38-14-19-020-050
 A. Removal of the Limit Switch 5MP
 (Ref. Fig. 401/TASK 38-14-19-991-001)

 (1)
 Disconnect the electrical connector 5MP-A (6).

 (2)
 Put blanking caps on the disconnected electrical connectors.

 (3)
 Remove and discard the lockwire from the nut (1).

 (4)
 Remove the nut (1), the washer (2) and the limit switch 5MP (5) and the O-ring (4).


R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-14-19Page 402 1 1 May 01/05 1 1 1CES 1


 Fill Condition Limit Switch
 Figure 401/TASK 38-14-19-991-001

R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-14-19Page 403 1 1 May 01/05 1 1 1CES 1

 TASK 38-14-19-400-001


 Installation of the Fill - Condition Limit - Switch (5MP)
 NOTE : The Fill-Condition Limit-Switch 5MP is refered to in the subsequent
____ procedure as the Limit Switch 5MP.
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific  1 WARNING NOTICE
 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
Material No. 19-009  USA AMS 5687 LOCKWIRE STAINLESS STEEL ANNEALED 0.5MM DIA (Ref. 20-31-00)
 C. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn