R **ON A/C 301-399,
R (Ref. Fig. 001B) R _______________________________________________________________________________ R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA R | | | | DOOR | REF. R -------------------------------------------------------------------------------R 31MG VACUUM SYSTEM CONTROLLER 162 38-31-34 R 37MG VACUUM GENERATOR 172 38-31-64 R 40MG LIQUID LEVEL TRANSMITTER 172 38-31-62 R 41MG LIQUID LEVEL SENSOR 172 38-31-63 R 43MG ALTITUDE PRESSURE SWITCH 312 312AR 38-31-00 R 50MG1 TOILET ASSEMBLY (LAV A) 221 38-31-41 R 50MG TOILET ASSEMBLY (LAV B) 221 38-31-41 R 50MG2 TOILET ASSEMBLY (LAV D) 261 38-31-41 R 50MG4 TOILET ASSEMBLY (LAV E) 262 38-31-41 R 3300MM WASTE HOLDING TANK 172 38-31-61 R 3302MM WATER SEPARATOR 172 38-31-67 R 3320MM CHECK VALVE (VACUUM PRESSURE) 172 38-31-65 R 3322MM CHECK VALVE (RINSE LINE) 172 38-31-76 R 3340MM WASTE DRAIN BALL VALVE 172 38-31-71 R 3341MM DRAIN VALVE CONTROL HANDLE 172 172AR 38-31-73 R 3345MM WASTE DRAIN VALVE-SERVICE 172 172AR 38-31-72
R 1EFF : 001-049, 051-099, 101-149, 151-199, 1 38-31-00Page 8 1201-299, 301-399, 1Aug 01/05 1 1 1CES 1


R **ON A/C 401-499,


R (Ref. Fig. 001B)
R _______________________________________________________________________________
R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA
R | | | | DOOR | REF.
R -------------------------------------------------------------------------------
R 37MG VACUUM GENERATOR R 40MG LIQUID LEVEL TRANSMITTER R 41MG LIQUID LEVEL SENSOR R 50MG1 TOILET ASSEMBLY (LAV A) R 50MG2 TOILET ASSEMBLY (LAV D) R 50MG4 TOILET ASSEMBLY (LAV E) R 3300MM WASTE HOLDING TANK R 3302MM WATER SEPARATOR R 3320MM CHECK VALVE (VACUUM PRESSURE) R 3322MM CHECK VALVE (RINSE LINE) R 3340MM WASTE DRAIN BALL VALVE R 3341MM DRAIN VALVE CONTROL HANDLE R 3345MM WASTE DRAIN VALVE-SERVICE R
 **ON A/C ALL
 3. System Description
__________________172 38-31-64 172 38-31-62 172 38-31-63 221 38-31-41 261 38-31-41 262 38-31-41 172 38-31-61 172 38-31-67 172 38-31-65 172 38-31-76 172 38-31-71 172 172AR 38-31-73 172 172AR 38-31-72
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, **ON A/C 001-003, 051-052, (Ref. Fig. 001) R **ON A/C 004-049, 053-099, 101-105, 151-199, 201-299, (Ref. Fig. 001A)

R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 (Ref. Fig. 002)
R 1EFF : ALL 1 38-31-00Page 9 1 1 Aug 01/05 1 1 1CES 1


 Vacuum Toilet System - Schematic
 Figure 002

R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 38-31-00Page 10 1201-299, 1Aug 01/05 1 1 1CES 1 The system uses potable water from the aircraft pressurized water system to flush the toilet. A vacuum drain removes waste from the toilet bowl to an underfloor waste holding tank. An electronic vacuum system controller controls the system and related electronic components. The toilet system is divided into:


 -
The cabin installation


 -
The cabin underfloor installation.
 The cabin installation has a single toilet assembly in each lavatory. The
 cabin underfloor installation has:

 

 -
A waste holding tank assembly


 -
A Liquid Level Transmitter (LLT) (tank mounted)


 -
A Liquid Level Sensor (LLS) (tank mounted)


 -
A vacuum generator


 -
A Vacuum System Controller (VSC)


 -
A check valve (vacuum pressure)

 

 -An altitude pressure switch

 -
A check valve (installed in each flush Line of the waste tank)


 -
A waste drain valve


 -
A waste service panel

 

 -The pipelines (overfloor and underfloor).


R **ON A/C 106-149, 301-399, 401-499,
R  (Ref. Fig. 001B, 002A) The system uses potable water from the aircraft pressurized water system to flush the toilet. A vacuum drain removes waste from the toilet bowl to an underfloor waste holding tank. The vacuum toilet system is connected to the CIDS system which controls the system function and related electronic components. The toilet system is divided into:
 -
The cabin installation


 -
The cabin underfloor installation.
 The cabin installation has a single toilet assembly in each lavatory.
 The cabin underfloor installation has:

 

 -
A waste holding tank assembly


 -
A Liquid Level Sensor (LLS) (tank mounted)


 -
A Liquid Level Transmitter (LLT) (tank mounted)


 -
A vacuum generator


 -
A check valve (vacuum pressure)


 -
A check valve (installed in each flush line of the waste tank)


 -
A waste drain valve
 