 - the overflow valve control light comes on.
 - fill the potable water tank with 50.0 l (13.21 USgal) of water. - the quantity indicator 6MA shows 1/4full.
 On the Forward Attendant Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH:
 - the quantity indicator shows 25%.
 2. At the service panel 2023VU: - push and hold the door limit switch 5MA.  On the FAP 120RH/miscellaneous panelWATER AND WASTE 124RH:- there is no indication.
 3. At the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH: - push and hold the membrane switch 'IND ON'. On the FAP 120RH/miscellaneous panelWATER AND WASTE 124RH:- the quantity indicator shows 25%.
 4. At the service panel 2023VU:  At the service panel 2023VU:

 

 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-fill the potable water tank with 100.0 l (26.42 USgal) of water.
 5. At the service panel 2023VU:
-push and hold the door limit switch 5MA.
6. At the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
-push and hold the membrane switch 'IND ON'.
 7. At the service panel 2023VU:
-fill the potable water tank with 150.0 l (39.63 USgal) of water.
 8. At the service panel 2023VU:
-push and hold the door limit switch 5MA.
9. At the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
-push and hold the membrane switch 'IND ON'.
 10. At the service panel 2023VU:
-fill the potable water tank with 200 l (52.83 USgal) of water.
-
the quantity indicator 6MA shows 1/2full.

 On the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:

 -
the quantity indicator shows 50% full.


On the FAP 120RH/miscellaneous panelWATER AND WASTE 124RH:
-there is no indication.
On the FAP 120RH/miscellaneous panelWATER AND WASTE 124RH:
-
the quantity indicator shows 50%.

At the service panel 2023VU:

-
the quantity indicator 6MA shows 3/4full.

 On the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:

 -
the quantity indicator shows 75% full.


On the FAP 120RH/miscellaneous panelWATER AND WASTE 124RH:
-there is no indication.
On the FAP 120RH/miscellaneous panelWATER AND WASTE 124RH:
-
the quantity indicator shows 75%.

At the service panel 2023VU:

-
the quantity indicator 6MA showsfull.

-
the motorized fill/drain valve 16MA closes.

 -
the TANK FULL control light comes on.


R 1EFF : 001-049, 051-099, 101-149, 201-299, 1 38-13-00Page 503 1 1 May 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
11. At the service panel 2023VU:
-push and hold the door limit switch 5MA.
12. At the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
-push and hold the membrane switch 'IND ON'.

R **ON A/C 151-199, 301-399, 401-499,
 Subtask 38-13-00-710-050-A
 A. Do this test.
 -
the overflow valve control light goes off.

 -
the fill and drain handle goes back to the NORMAL position.

 On the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:

 -
the quantity indicator shows 100% full.


On the FAP 120RH/miscellaneous panelWATER AND WASTE 124RH:
-there is no indication.
On the FAP 120RH/miscellaneous panelWATER AND WASTE 124RH:
-the quantity indicator shows 100%.
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. At the service panel 2023VU: - put the fill and drain handle to the FILL position.  At the service panel 2023VU:- fill the potable water tank with 55.0l (14.53 USgal) of water. - the quantity indicator 6MA shows 1/4 full.
 At the Forward Attendant Panel (FAP) 120RH/miscellaneous panel WATER AND WASTE 124RH:
 - the quantity indicator shows 25% full.

 

 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
2. At the service panel 2023VU:
-push and hold the door limit switch 5MA.
3. At the FAP 120RH/miscellaneous panel WATER AND WASTE 124RH:
-push and hold the membrane switch 'IND ON'.
4. At the service panel 2023VU:
-fill the potable water tank with 110.0 l (29.06 USgal) of water.
 5. At the service panel 2023VU:
 