A. Aircraft Maintenance Configuration
(1)
Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002).
(2)
On one MCDU, get the SYSTEM REPORT/TEST INST menu page (Ref. TASK 31-32-00-860-008).
1EFF : 106-149, 229-299, 303-399, 401-499, 1 31-50-00Page 537 1 1 Aug 01/05 1 1 1CES 1 Subtask 31-50-00-865-072
B. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------
PANEL ------ DESIGNATION -------------------------------------------- IDENT. LOCATION-----------------------------
49VU SDAC/1/SPLY 3WV F04
49VU SDAC/2/26VAC SYNC/AC ESS BUS 6WV F03
49VU SDAC/1/26VAC SYNC/AC ESS BUS 5WV F02
49VU FWS/FWC1/SPLY 3WW F01
121VU EIS/FWC2/SPLY 2WW Q07
121VU EIS/SDAC/2/SPLY 2WV Q06
121VU EIS/SDAC/1/BUS2/26VAC SYNC AC 7WV Q03
121VU EIS/SDAC/2/BUS2/26VAC SYNC AC 8WV Q02
4. Procedure_________
Subtask 31-50-00-740-052
A. Test
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
On the MCDU, push the line key adjacent to the ECAM 1 indication.
2.
Push the next page key.
3.
Push the line key adjacent to the SYSTEM CONFIGURATION indication.
4.
Push the line key adjacent to the ECAM PIN PROGRAM SOFT indication.
On the MCDU, theECAM-1/FWC1/2-SDAC1/2-ECP page comesinto view.
The ECAM-1/FWC1/2-SDAC1/2-ECP next page comes into view.
The ECAM-1/SYSTEM CONFIGURATION pagecomes into view.
The ECAM-1/ECAM PIN PROGRAM SOFT pagecomes into view.
1EFF : 106-149, 229-299, 303-399, 401-499, 1 31-50-00Page 538 1 1 Aug 01/05 1 1 1CES 1
5. Close-up
________ Subtask 31-50-00-860-090
A. Put the aircraft back to its initial configuration.
(1)
On the MCDU, push the line key adjacent to the RETURN indication until the CFDS MENU page comes into view.
(2)
De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002)
(3)
Put the system back to the serviceable condition.
(4)
Put the aircraft back to the serviceable condition.
1EFF : 106-149, 229-299, 303-399, 401-499, 1 31-50-00Page 539 1 1 Aug 01/05 1 1 1CES 1R **ON A/C ALL
R TASK 31-50-00-710-011 R Operational Test of the MASTER CAUT and MASTER WARN lights R 1. Reason for the Job
__________________ R To make sure that the MAST WARN and MAST CAUT lights operate correctly. R 2. Job Set-up Information
______________________
R A. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 24-41-00-861-002 R R 24-41-00-862-002 R R 31-60-00-860-001 R 31-60-00-860-002
R 3. Job Set-up
__________
R Subtask 31-50-00-860-093 Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power EIS Start Procedure EIS Stop Procedure
R A. Aircraft Maintenance Configuration
R Energize the aircraft electrical circuits
R (Ref. TASK 24-41-00-861-002)
R Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only)
R (Ref. TASK 31-60-00-860-001)
1EFF : ALL 1 31-50-00Page 540 1 1 Aug 01/05 1 1 1CES 1 1EFF : ALL 1 31-50-00Page 541 1 1 Aug 01/05 1 1 1CES 1
R Subtask 31-50-00-865-077
R B. Make sure that this(these) circuit breaker(s) is(are) closed:
R -------------------------------------------------------------------------------
R PANEL DESIGNATION IDENT. LOCATION
R -------------------------------------------------------------------------------
R 49VU ENGINE/2/FIRE DET/LOOP B 8WD2 A07
R 49VU ENGINE/1/FIRE DET/LOOP A 7WD1 A06
R 49VU SDAC/1/SPLY 3WV F04
R 49VU SDAC/2/26VAC SYNC/AC ESS BUS 6WV F03
R 49VU SDAC/1/26VAC SYNC/AC ESS BUS 5WV F02
R 121VU EIS/SDAC1 AND 2/BUS2/28VDC 44WV P03
R 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B 2WE1 Q44
R 121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A 1WE1 Q43
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 5(165)