ACTION RESULT -------------------------------------------------------------------------------
8.
 Release the ENG1 loop/squib TEST  - the warnings go out of view, except pushbutton switch. FWS FWC1 FAULT

 - on the lower ECAM DU: *the DOOR/OXY page comes into view.

 9.
 Close the circuit breaker 3WW.  - on the upper ECAM DU: FWS FWC1 FAULT goes out of view.

 10.
 Push the MASTER light if it is on.


 5. Close-up
________
 Subtask 31-50-00-860-053
 A. Put the aircraft back to its initial configuration.
 (1)
 On the ECAM control panel, set the UPPER DISPLAY and LOWER DISPLAY potentiometers to OFF.

 (2)
 De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002)


 (3)
 Make sure that the work area is clean and clear of tool(s) and other items.


 1EFF : ALL 1 31-50-00Page 507 1 1 Feb 01/98 1 1 1CES 1


 TASK 31-50-00-710-003 Operational Test of the System Data Acquisition Concentrator (SDAC) WARNING : MAKE SURE THAT ALL THE CIRCUITS IN MAINTENANCE ARE ISOLATED BEFORE
_______ YOU SUPPLY ELECTRICAL POWER TO THE AIRCRAFT.
 1.
 Reason for the Job

__________________
 Make sure that the amber visual and audio cautions are operated by a SDAC.


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 31-60-00-860-001 EIS Start Procedure
 3. Job Set-up
__________ Subtask 31-50-00-860-054
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002)


 (2)
 Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001)


 1EFF : ALL 1 31-50-00Page 508 1 1 Feb 01/98 1 1 1CES 1 Subtask 31-50-00-865-055


 B. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------
PANEL ------ DESIGNATION -------------------------------------------- IDENT. LOCATION-----------------------------
49VU SDAC/1/SPLY  3WV  F04
 49VU SDAC/2/26VAC SYNC/AC ESS BUS  6WV  F03
 49VU SDAC/1/26VAC SYNC/AC ESS BUS  5WV  F02
 121VU EIS/SDAC1 AND 2/BUS2/28VDC  44WV  P03
 121VU EIS/SDAC/2/SPLY  2WV  Q06
 121VU EIS/SDAC/1/BUS2/26VAC SYNC AC  7WV  Q03
 121VU EIS/SDAC/2/BUS2/26VAC SYNC AC  8WV  Q02
 4. Procedure_________
 Subtask 31-50-00-710-053
 A. Test

 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
 On the panel 121VU : - open the circuit breaker 2WV .

- open the circuit breaker 44WV.

2.
 On the glareshield :


 -push then release the CAPT or F/O MASTER CAUT pushbutton switch.
 3. On the panel 121VU :- on the upper ECAM DU:
 * the FWS SDAC2 FAULT indication
 comes into view.

* the ELEC DC BUS2 FAULT indication
 comes into view.
 - on the lower ECAM display unit:

 * the ELEC page comes into view.
 -you hear the single chime. - on the glareshield :
 * the CAPT and F/O MASTER CAUT lights come on.
-the CAPT and F/O MASTER CAUT lightsgo off.
 1EFF : ALL 1 31-50-00Page 509 1 1 Feb 01/98 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-
close the circuit breaker 44WV.

-
close the circuit breaker 2WV.


4. On the ECAM control panel:
 -push the CLR key to reset all warnings.
5.
 On the panel 49VU : - open the circuit breaker 3WV .

6.
 On the panel 121VU : - open the circuit breaker 44WV.


-close the circuit breaker 44WV.
7. On the panel 49VU :
 -close the circuit breaker 3WV .
- on the upper ECAM display unit:
 * the warning message goes out of
 view. - on the lower ECAM display unit:
 