-FMGC2
NOT SELECTED
-CFDIU
NOT SELECTED
-ATSU
NOT SELECTED
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-00Page 36 1401-499, 1Config-2 Aug 01/05 1 1 1CES 1 **ON A/C 159-199, 210-210,
-ACMS
NOT SELECTED
-DFDRS
NOT SELECTED
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
-TCAS
NOT SELECTED
R **ON A/C 106-149, 303-399, 401-499,
-DMC1
NOT SELECTED
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
(b) List of messages when the loading procedure is in progress
-DLRB
SELECTED
-FMGC1
SELECTED
-FMGC2
SELECTED
-CFDIU
SELECTED
-ATSU
SELECTED
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-00Page 37 1401-499, 1Config-2 Aug 01/05 1 1 1CES 1 **ON A/C 159-199, 210-210,
-ACMS
SELECTED
-FDR SYS
SELECTED
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
-TCAS
SELECTED
R **ON A/C 106-149, 303-399, 401-499,
-DMC1
SELECTED
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
(2) List of Fault messages
(a) Selected channel failure after action SEL CTL key
-DLRB CHAN FAIL PUSH SEL CTL
-FMGC1 CHAN FAIL PUSH SEL CTL
-FMGC2 CHAN FAIL PUSH SEL CTL
-CFDIU CHAN FAIL PUSH SEL CTL
-ATSU CHAN FAIL PUSH SEL CTL
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-00Page 38 1401-499, 1Config-2 Aug 01/05 1 1 1CES 1 **ON A/C 159-199, 210-210,
-ACMS CHAN FAIL
PUSH SEL CTL
-FDR SYS CHAN FAIL
PUSH SEL CTL
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
-TCAS CHAN FAIL
PUSH SEL CTL
R **ON A/C 106-149, 303-399, 401-499,
-DMC1 CHAN FAIL
PUSH SEL CTL
R **ON A/C 106-149, 151-199, 201-299, 301-399, 401-499,
(3) Other messages
(a) Message when DLS is powered, when going through the step menu or at the end of the DLRB loading procedure
DB/N:
PUSH NEXT/PREV
NOTE : the name of the data base follows the DB/N: indication
____ except if the DLRB has never been loaded.
(b) Automatic display after failure of a DLRB loading procedure
UP-LOADING ERROR
PUSH SEL CTL
Fault symptom origin:
-unwritten in EEPROM data base
-abnormal interrupt of the protocol with the MDDU (as per ARINC 615)
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-00Page 39 1401-499, 1Config-2 Aug 01/05 1 1 1CES 1
(c) STANDBY message
STANDBY PUSH NEXT/PREV This menu is displayed before the programmed scrolling menu
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-00Page 40 1401-499, 1Config-2 Aug 01/05 1 1 1CES 1
6. Component Description
_____________________
A. MDDU Description (Ref. Fig. 005) The front panel contains:
-
a window with a 16-character alphanumeric LCD display
-
a door protecting access to the disk drive (the display is always visible whether the access door is open or closed).
(1)
door closed the MDDU is protected against entry of dust and liquids.
(2)
door open the MDDU is not protected against entry of liquids.
The disk drive is protected against entry of dust by its own internal protection.
The MDDU can work with the door open or closed by the later method is preferable as shown by the KEEP DOOR CLOSED indication on the internal face of the door.
The disk is ejected by means of a disk extraction pushbutton switch located below the disk access slot. This pushbutton switch can only be used when the access door is open.
This switch is surrounded by a fluorescent label (green color).
(3) Mechanical characteristics
(a)
Size
(b)
Weight: 1.975 kg
(c)
Attachment: by 4 quarter-turn fasteners.
1_ Height: 95.2 mm
2_ Width: 146 mm
3_ Depth: 194.5 mm
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-00Page 41 1401-499, 1Config-2 Aug 01/05 1 1 1CES 1
Multipurpose Drive Disk (MDDU)
Figure 005