• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-25 12:19来源:蓝天飞行翻译 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 3. Job Set-up
__________ Subtask 31-38-21-862-050
 A. De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002).

 Subtask 31-38-21-865-050
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU DATA/LOADER/SPLY 3TD J16 121VU DLS&/DLRB/SPLY 5TD J15
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-21Page 401 1401-499, 1Aug 01/05 1 1 1CES 1


 4. Procedure
_________
 (Ref. Fig. 401/TASK 31-38-21-991-001) Subtask 31-38-21-020-050
 A. Removal of the Data Loading Selector
 (1)
 Hold the data loading selector panel (2) and loosen the quarter-turn fasteners (3).

 (2)
 Pull the data loading selector panel (2) from its housing.

 (3)
 Disconnect the electrical connector (1).

 (4)
 Remove the data loading selector (2).

 (5)
 Put blanking caps on the disconnected electrical connectors.


R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-21Page 402 1401-499, 1Aug 01/05 1 1 1CES 1


 Data Loading Selector (101TD)
 Figure 401/TASK 31-38-21-991-001

R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-21Page 403 1401-499, 1Aug 01/05 1 1 1CES 1


 TASK 31-38-21-400-001
 Installation of the Data Loading Selector (101TD)

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 31-38-21-991-001 Fig. 401
 3. Job Set-up
__________ Subtask 31-38-21-860-050
 A. Make sure that the aircraft electrical circuits from the external power is de-energized (Ref. TASK 24-41-00-862-002).
 Subtask 31-38-21-865-052
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU DATA/LOADER/SPLY 3TD J16 121VU DLS&/DLRB/SPLY 5TD J15
R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-21Page 404 1401-499, 1Aug 01/05 1 1 1CES 1


 4. Procedure
_________
 (Ref. Fig. 401/TASK 31-38-21-991-001) Subtask 31-38-21-420-050
 A. Installation of the data loading selector
 (1)
 Clean the component interface and/or the adjacent area.

 (2)
 Do an inspection of the component interface and/or the adjacent area.

 (3)
 Remove the blanking caps from the electrical connectors.

 (4)
 Make sure that the electrical connectors are clean and in the correct condition.

 (5)
 Make sure that the housing of the Data Loading Selector is clean and clear of tool(s) and other items.

 (6)
 Connect the electrical connector (1).

 (7)
 Install the data loading selector (2) in its housing.


 (8)
 Tighten the quarter-turn fasterners. Subtask 31-38-21-865-053

 B.
 Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 3TD, 5TD.


 Subtask 31-38-21-861-050
 C. Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).

R 1EFF : 106-149, 151-199, 201-299, 301-399, 1 31-38-21Page 405 1401-499, 1Aug 01/05 1 1 1CES 1 Subtask 31-38-21-710-050


 D. Test
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the overhead panel:
-set the Data Loading Selector ON/OFF switch to ON.
2. On the overhead panel:
-set the Data Loading Selector PREV or NEXT P/B switches until you select the FMGC1 indication
3. On the overhead panel:
-Push the Data Loading Selector SEL CTL P/B switch
4. On the overhead panel:
-Push the Data Loading Selector SEL CTL P/B switch
5. Close-up
________
 Subtask 31-38-21-860-051On the Data Loading Selector screen:
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM 指示/记录系统 5(137)