 HYDRAULIC FLUID (PHOSPHATE ESTER BASE)
 (Ref. 20-31-00)

R 1EFF : 001-049, 051-058, 101-101, 1 29-19-51Page 441 1 1 May 01/05 1 1 1CES 1


 C. Expendable Parts -------------------------------------------------------------------------------
FIG.ITEM --------- |DESIGNATION ------------------------------------ |IPC-CSN----------------------------------
4  packings  29-19-51 01 -020
 4  packings  29-19-51 02 -020
 D. Referenced Information

 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
20-28-00-912-004  Electrical Bonding of Components With Conductive
 Bolts and Screws and Bonding Straps in the Fuselage
 and in the Wings (this does not include the tanks)-
24-41-00-861-002  Energize the Aircraft Electrical Circuits from the
 External Power
 24-41-00-862-002  De-energize the Aircraft Electrical Circuits Supplied
 from the External Power
 29-00-00-910-002  Safety Procedures of the Hydraulic System
 29-10-00-863-001  Pressurize the Green Hydraulic System
 29-10-00-863-002  Pressurize the Yellow Hydraulic System
 29-10-00-863-003  Pressurize the Blue Hydraulic System with a Ground
 Power Supply
 29-10-00-864-001  Depressurize the Green Hydraulic System
 29-10-00-864-002  Depressurize the Yellow Hydraulic System
 29-10-00-864-003  Depressurize the Blue Hydraulic System
 29-14-00-614-002  Pressurization of the Hydraulic Reservoirs through
 the Ground Connector
 29-23-00-860-002  Connection of the Isolation Coupling of the Power
 Transfer Unit (PTU)
 31-60-00-860-001  EIS Start Procedure
 31-60-00-860-002  EIS Stop Procedure
 29-19-51-991-004  Fig. 404
 29-19-51-991-005  Fig. 405
 FOR FIN 1150GP
 29-00-00-864-001  Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action
 29-14-00-614-001  Depressurization of the Hydraulic Reservoirs
 29-23-00-860-001  Disconnection of the Isolation Coupling of the Power
 Transfer Unit (PTU)
 32-12-00-410-001  Close the Main Gear Doors after Access
 FOR FIN 2150GP 

R 1EFF : 001-049, 051-058, 101-101, 1 29-19-51Page 442 1 1 May 01/05 1 1 1CES 1 -------------------------------------------------------------------------------


REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs FOR FIN 3150GP 29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
 Configuration before Maintenance Action
 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs

 3. Job Set-up
__________
 Subtask 29-19-51-860-057
 A. Aircraft Maintenance Configuration
 WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
 (1)
 Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).

 (2)
 Make sure that the container is in position below the replacement pilot valve .

 

R (3) FOR 1150GP
 (a)
 Make sure that the Green hydraulic system is depressurized and put it in the maintenance configuration (Ref. TASK 29-00-00-864-001).

 (b)
 Make sure that the reservoir of the Green hydraulic system is depressurized (Ref. TASK 29-14-00-614-001).

 (c)
 Make sure that the isolation coupling of the Power Transfer Unit (PTU) is disconnected (Ref. TASK 29-23-00-860-001).

 (d)
 Make sure that one MLG door is open.

 (e)
 Make sure that the access platform is in position.

 (f)
 Make sure that the warning notices are in position to tell persons not to pressurize the Green hydraulic system:


 -in the cockpit on the hydraulic section 40VU of the overhead
 panel. - on the ground service panel of the Green hydraulic system.
R 1EFF : 001-049, 051-058, 101-101, 1 29-19-51Page 443 1 1 May 01/05 1 1 1CES 1R (4) FOR 2150GP

 

 (a)
 Make sure that the Blue hydraulic system is depressurized and put it in the maintenance configuration (Ref. TASK 29-00-00-864-001).

 (b)
 Make sure that the reservoir of the Blue hydraulic system is depressurized (Ref. TASK 29-14-00-614-001).
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压5(89)