 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific 1 ACCESS PLATFORM 3M (10 FT)
 No specific 1 CONTAINER 1 L (1/4 USGAL)
 No specific 2 WARNING NOTICE

 B. Consumable Materials
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R  Material No. 02-003 F NSA 307110 TYPE 4 HYDRAULIC FLUID (PHOSPHATE ESTER BASE) (Ref. 20-31-00)
 C. Expendable Parts
 -------------------------------------------------------------------------------FIG.ITEM |DESIGNATION |IPC-CSN -------------------------------------------------------------------------------
5 packing (1) 29-16-11 01 -060 6 packings (2) 29-16-11 01 -050R D. Referenced Information


R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 29-00-00-864-001 R R 29-00-00-910-002 R 29-14-00-614-001 R 29-16-11-991-001
R 3. Job Set-up
__________ Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action Safety Procedures of the Hydraulic System Depressurization of the Hydraulic Reservoirs Fig. 301
R Subtask 29-16-11-010-052 R A. Open the access panel 197CB. R Subtask 29-16-11-860-052 R B. Aircraft Maintenance Configuration R WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
R (1) Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
R (2) Put a WARNING NOTICE in position to tell persons not to pressurize
R the Green hydraulic system:
R - In the cockpit on the hydraulic panel 40VU of the overhead panel,
R - On the ground service panel of the Green hydraulic system.

R (3) Make sure that the Green hydraulic system is depressurized and put it
R in the maintenance configuration.
R (Ref. TASK 29-00-00-864-001).

R (4) Depressurize the reservoir of the Green hydraulic system (Ref. TASK
R 29-14-00-614-001).

R (5) Put the ACCESS PLATFORM 3M (10 FT) in position.

R (6) Put the CONTAINER 1 L (1/4 USGAL) below the filter to collect the
R unwanted hydraulic fluid.

 

R  4. Procedure_________ 
R  (Ref. Fig. 301/TASK 29-16-11-991-001) 
R  Subtask 29-16-11-020-051 
R  A. Removal of the Clogging Indicator 
R  (1) Loosen and remove the clogging indicator (4) from the filter head 
R  (1). 
R  (2) Remove and discard the packings (5) and (6) from the clogging 
R  indicator (4). 
R  Subtask 29-16-11-560-051 
R  B. Preparation for Installation 
R  (1) Lubricate the new packing (5) and the new packings (6) with the 
R  HYDRAULIC FLUIDS (Material No. 02-003) and install them on the 
R  clogging indicator (4). 
R  (2) Lubricate the threads of the clogging indicator (4) with the 
R  HYDRAULIC FLUIDS (Material No. 02-003). 
R  Subtask 29-16-11-420-051 
R  C. Installation of the Clogging Indicator 
R  (1) Clean the component interface and/or the adjacent area. 
R  (2) Do an inspection of the component interface and/or the adjacent area. 
R  (3) Install the clogging indicator (4) in the filter head (1). 
R  Subtask 29-16-11-790-052 
R  D. Test of the Filter Assembly 
R  (1) Remove the warning notice(s). 
R  (2) Remove the blanking cap from the reservoir fill valve 1698GM. 
R  (3) Connect the flexible hose 1699GM to the fill valve. 
R  (4) Put the end of the flexible hose into a container of the HYDRAULIC 
R  FLUIDS (Material No. 02-003).

 

R  (5) Make sure that the reservoir filling selector 1134GQ is set to 'N'. 
R  (6) Operate the hand pump through three or four cycles to pressurize the 
R  filter. 
R  NOTE : A Pressure relief valve in the filling selector valve will____ 
R  operate if too much pressure is put into the system. If this 
R  occurs, a small amount of fluid will go into the reservoir of 
R  the Yellow system. 
R  (7) Make sure that no fluid comes out of the filter. 
R  (8) Make sure that the clogging indicator stays in. 
R  (9) Momentarily set the reservoir filling selector to one of the 
R  reservoir positions (G, Y or B) to release the hydraulic pressure. 
 