PUMP - HAND (1009GM) - REMOVAL/INSTALLATION
___________________________________________ TASK 29-16-42-000-001 Removal of the Hand Pump (1009GM) WARNING : OBEY THE HYDRAULIC SAFETY PROCEDURES.
_______
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps No specific blanking plug No specific warning notice No specific access platform 1.76 m (5 ft. 9 in.) No specific container 5.0 l (1.3208 USgal)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
29-00-00-864-001 Put the Related Hydraulic System in the Depressurized
Configuration before Maintenance Action 29-00-00-910-002 Safety Procedures of the Hydraulic System 29-14-00-614-001 Depressurization of the Hydraulic Reservoirs 29-16-42-991-001 Fig. 401
3. Job Set-up
__________ Subtask 29-16-42-010-050
A. Get Access
(1)
Remove the access panel 197BB.
(2)
Put the access platform in position below the ground service panel of the Green hydraulic system.
Subtask 29-16-42-860-050
B. Aircraft Maintenance Configuration
(1)
Obey the hydraulic safety procedures (Ref. TASK 29-00-00-910-002).
(2)
Put the warning notice in position to tell persons not to pressurize the hydraulic systems:
-in the cockpit on the hydraulic section 40VU of the overhead panel.
(3)
Make sure that the hydraulic systems are depressurized and put them in the maintenance configuration. (Ref. TASK 29-00-00-864-001).
(4)
Depressurize the reservoirs of the Green ,Yellow and Blue hydraulic systems (Ref. TASK 29-14-00-614-001).
(5)
Put the container below the hydraulic connections to collect the hydraulic fluid.
4. Procedure
_________ (Ref. Fig. 401/TASK 29-16-42-991-001) Subtask 29-16-42-020-050
A. Removal of the Hand Pump CAUTION : USE A SECOND WRENCH TO APPLY COUNTERTORQUE TO THE UNION WHEN
_______ YOU DISCONNECT/CONNECT HYDRAULIC LINES ON UNIONS. IF YOU USE THE SECOND WRENCH, YOU WILL NOT LOOSEN OR TIGHTEN THE UNION TOO MUCH.
(1)
Loosen the union nut (7) and remove the pipe from the adapter (8).
(2)
Put a blanking plug on the disconnected line end.
(3)
Remove the bolts (15) and the washers (16) from the bracket (17).
(4)
Remove the screws (4) and the washers (5).
(5)
Remove the bracket (17) from the ground service panel (6).
(6)
Hold the hand pump (3).
(7)
Remove the bolts (20) and the washers (19) from the bracket (18).
(8)
Pull the hand pump (3) out of the ground service panel (6).
(9)
Remove the adapter (8) and the O-ring (11). Discard the O-ring.
Hand Pump
Figure 401/TASK 29-16-42-991-001
1EFF : ALL 1 29-16-42 Page 403
1 1 Feb 01/98
1 1
1CES 1
(10)
Remove the plug (9) and the O-ring (10). Discard the O-ring.
(11)
Remove the fill valve (1) and the O-ring (2). Discard the O-ring.
(12)
Put blanking caps on the ports of the hand pump.
TASK 29-16-42-400-001
Installation of the Hand Pump (1009GM)
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM HYDRAULIC POWER 液压5(57)