(2)
Connect the electrical connector to the related smoke detector.
(3) Repeat paragraphs 3.A. to 3.D. for each lavatory smoke detector. Subtask 26-17-00-865-052
E. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 11WQ, 12WQ
Subtask 26-17-00-710-051
F. Do the test with the CFDS (Ref. TASK 31-32-00-860-005).
5. Close-up
________
**ON A/C 001-003, 051-052,
Subtask 26-17-00-410-050
A. For installation of items removed for access, refer to relevant lavatory:
-
LAV A (Ref. TASK 26-17-15-400-001)
-
LAV D (Ref. TASK 26-17-15-400-002)
-
LAV E (Ref. TASK 26-17-15-400-004)
**ON A/C 004-049, 053-099, 101-105, 151-199, 201-299,
Subtask 26-17-00-410-056
B. For installation of items removed for access, refer to the related
lavatory:
-
LAV A (Ref. TASK 26-17-15-400-001)
-
LAV B, D, E, F, H, K, L and M (Ref. TASK 26-17-15-400-007)
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
Subtask 26-17-00-862-050
C. De-energize the aircraft electrical circuits
(Ref. TASK 24-41-00-862-002).
DETECTOR - SMOKE - REMOVAL/INSTALLATION
_______________________________________
TASK 26-17-15-000-001 Removal of the Lavatory Smoke Detector 1WQ
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power
3. Job Set-up
__________ Subtask 26-17-15-861-054
A. Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002)
1EFF : ALL 1 26-17-15Page 401 1 1 Feb 01/04R 1 1 1CES 1
Subtask 26-17-15-865-050
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
49VU AIR COND/SDCU/CHAN1 11WQ C06 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-399,
49VU COM/CIDS/DEU B/ESS 153RH G03 **ON A/C 001-049, 051-099, 101-105, 201-299,
121VU COM NAV/CIDS/DEU B/NORM 162RH M07 R **ON A/C 106-149, 151-199, 401-499,
121VU COM NAV/CIDS/DEU B/NORM 162RH M08 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
122VU AIR COND/SDCU/CHAN2 12WQ T18 **ON A/C 001-003, 051-052,
Subtask 26-17-15-010-050
C. Get Access
(1) Carefully pull the air-extraction grill (2) away from the air-extraction hood (3).
R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
Subtask 26-17-15-010-050-A
C. Get Access
(1)
Remove the the screws (11) and the air-extraction grill (10).
(2)
Remove the air filter (12) and the grill (13) from the air-extraction hood (8).
**ON A/C ALL
4. Procedure
_________ **ON A/C 001-003, 051-052,
Subtask 26-17-15-020-050
A. Removal of the Lavatory Smoke Detector
WARNING : DO NOT TRY TO OPEN OR REPAIR THE SMOKE DETECTORS.
_______ THE DETECTOR CONTAINS RADIOACTIVE AMERICIUM 241 OF APPROXIMATELY 0.4 MICROCURIES. ONLY WORKSHOPS AUTHORIZED BY THE MANUFACTURER CAN DO WORK ON THE SMOKE DETECTORS. 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(96)