• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:41来源:未知 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-Push the line key adjacent to the YES indication.
2. On the MCDU:
-
Push the line key adjacent to the RETURN indication.

-
Push the line key adjacent to the SMK DET AFT LDCC TEST indication.


On the glareshield panels 130VU and 131VU:
 -
The MASTER WARN lights flash.

 -
The continuous repetitive chime operates.


 On the ECAM upper display unit:
 -SMOKE FWD CARGO SMOKE
 -...AGENT...........DISCH come on.
 On the CARGO SMOKE panel 22VU:
 -The SMOKE FWD CARGO warning light comes on.
On the MCDU:
The SMK DET FWD LDCC TEST page comes on
 and shows:
 TEST OK

On the MCDU:

-The SMOKE WARNING TESTS menu comeson.
 On the CARGO SMOKE PANEL 22VU, on the ECAM upper display unit, on the glareshield panels 130VU and 131VU:
 -All smoke warnings and indications are cancelled.
On the MCDU:
-
The SMK DET AFT LDCC TEST page comeson and shows: INITIAL CONDITIONS: ON SYSTEM PAGE AIR COND MAKE SURE THAT THE AFT CARGO ISOL VALVES ARE IN OPEN POSITION

 On the ECAM lower display:

 -
The AFT isolation valve symbols show open.


R 1EFF : 106-149, 301-399, 401-499, 1 26-16-00Page 522 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-
Push line key adjacent to the YES indication.

 -
Push line key adjacent to the START TEST indication.

-
Push the line key adjacent to the YES indication.


On the glareshield panels 130VU and131VU:
 -
The MASTER WARN lights flash.

 -
The continuous repetitive chime operates.


 On the ECAM upper display unit:
 -SMOKE AFT CARGO SMOKE
 -...AFT ISOL VALVE....OFF
 -...AGENT...........DISCH come on.
 On the CARGO SMOKE panel 22VU:
 -The SMOKE AFT CARGO warning light comes on.
 On the ECAM upper display unit:
 -...AFT ISOL VALVE....OFF goes off.
 In the AFT cargo compartment:
 -
The two isolation valves close.

 -
The extraction fan stops.

 On the ECAM lower display unit:

 -
The two AFT isolation valve symbols close.

 On the MCDU:

 -
The SMK DET AFT LDCC TEST page shows: ON OVHD PANEL AND ECAM WARNING DISPLAY MAKE SURE THAT "SMOKE AFT CARGO SMOKE" IS INDICATED

-
The SMK DET AFT LDCC TEST shows:ON SYSTEM PAGE AIR COND MAKE SURE THAT THE AFT CARGO ISOL VALVES ARE IN CLOSED POSITION


R 1EFF : 106-149, 301-399, 401-499, 1 26-16-00Page 523 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
-Push the line key adjacent to the YES indication.
On the circuit breaker panel 49VU:
-Open then close circuit breaker 31HN.
 -Push line key adjacent to the YES indication.
3. On the MCDU:
-
Push the line key adjacent to the RETURN indication.

-
Push the line key adjacent to the RETURN indication.


 Open, safety and tag this(these) circuit breaker(s):
 -15WH on the panel 49VU.
 -17WH on the panel 122VU.
 On the MCDU:
-Push the line key adjacent to the SDCU indication.
On the CARGO SMOKE PANEL 22VU,on the ECAM upper display unit, on the glareshield panels 130VU and 131VU:
 -All smoke warnings and indications are cancelled.
 In the AFT cargo compartment:
 -
The AFT isolation valves remain in the fully closed position.

 On the MCDU:

 -
The SMK DET AFT LDCC TEST page shows: RESET AFT CARGO ISOL VALVES MAKE SURE THAT THE AFT CARGO ISOL VALVES ARE IN OPEN POSITION


In the AFT cargo compartment:
-After approx. 15 seconds, the twoisolation valves are open.
On the MCDU:
-
The SMK DET AFT LDCC page comes on and shows: TEST OK

On the MCDU:

-
The SMOKE WARNING TESTS menu comeson.

-
The CIDS-SDF main menu comes on.

-
The CIDS-SDF1 is de-energized.

On the MCDU:

-
The CIDS-SDF page comes on and shows:SDCU FUNCTION


R 1EFF : 106-149, 301-399, 401-499, 1 26-16-00Page 524 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(81)