 Install the screws (6) and tighten them.


 (7) Close the 3 safety guards (4). Subtask 26-12-12-865-058
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 7WD1, 8WD2, 7WD2, 8WD1, 1WE1, 1WE2, 1WE2, 2WE1, 2WE2, 1WG, 2WG, 1WF, 2WF, 3WF, 4WF, 1QG, 2QG, 3QG, 4QG, 1HB, 2HB, 2HA1, 3HA1, 2HA2, 3HA2, 2XU1, 2XU2, 23XU1, 23XU2, 24XU1, 24XU2, 26XU1, 26XU2, 1703GK, 3702GD
 Subtask 26-12-12-720-053
 C. Do this Functional Test:
 (1) Reset of the FIRE pushbutton switch: CAUTION : TO RESET THE ENG 1(2) APU FIRE PUSHBUTTON SWITCH:
_______
 -PUSH THE PUSHBUTTON SWITCH FULLY IN (LATCHED POSITION).
 THEN CLOSE THE GUARD.
 DO NOT TRY TO CLOSE THE GUARD AND PUSH THE PUSHBUTTON
 SWITCH AT THE SAME TIME.

 

 (a)
 Open the safety guard of the FIRE pushbutton switch.


 (b)
 Push and release the FIRE pushbutton switch.

 (c)
 Push the FIRE pushbutton switch.

 (d)
 Close the safety guard of the FIRE pushbutton switch.


 (2) Do a functional test of the ENG 1(2) FIRE pushbutton switch (Ref. TASK 26-21-00-720-005).
 Subtask 26-12-12-710-052
 D. Do this Operational Test:
 (1)
 For the APU:

 (a)
 Do an operational test of the functions of the APU FIRE pushbutton-switch (Ref. TASK 26-22-00-710-004).

 (b)
 Do an operational test of the APU fire-extinguishing system (Ref. TASK 26-22-00-710-001).

 

 (2)
 For the engine:


 (a) Do an operational test of the engine fire and overheat detection system (Ref. TASK 26-12-00-710-001).
 5. Close-up
________ Subtask 26-12-12-862-050
 A. De-energize the ground service network
 (Ref. TASK 24-42-00-862-001).

 Subtask 26-12-12-410-050
 B. Close Access
 (1)
 Make sure that the work area is clean and clear of tool(s) and other items.

 (2)
 Remove the warning notice(s).


 1EFF : ALL 1 26-12-12Page 420 1 1 Aug 01/05R 1 1 1CES 1


 DETECTOR - FIRE, FAN (LOOP A AND B) (4000WD1,4000WD2) - REMOVAL/INSTALLATION
____________________________________________________________________________ TASK 26-12-15-000-042 Removal of the Fan Fire Detectors (4000WD1,4000WD2) WARNING : BE CAREFUL WHEN YOU WORK ON THE ENGINE COMPONENTS IMMEDIATELY AFTER
_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS CAN STAY HOT FOR UP TO ONE HOUR.
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific circuit breaker(s) safety clip(s) No specific phillips head screw driver No specific protective covers No specific warning notice No specific access platform 1 m (3 ft. 3 in.)
 B. Referenced Information
 -------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-42-00-861-001 Energize the Ground Service Network from the External
 Power 71-13-00-010-040 Opening of the Fan Cowl Doors 26-12-15-991-300 Fig. 401
 3. Job Set-up
__________ Subtask 26-12-15-861-052
 A. Energize the ground service network (Ref. TASK 24-42-00-861-001).


 Subtask 26-12-15-941-050
 B. Safety Precautions
 (1) On the center pedestal, on the ENG panel 115VU: R (a) Put a warning notice to tell persons not to start the engine.
 (2)
 Make sure that the engine 1(2) shutdown occurred not less than 5 minutes before you do this procedure.

 (3)
 On the overhead maintenance panel 50VU:

 (a)
 Make sure that the ON legend of the ENG/FADEC GND PWR/1(2) pushbutton switch is off.

 (b)
 Put a warning notice to tell persons not to energize the FADEC 1(2).

 


 Subtask 26-12-15-010-050
 C. Get access
 (1) Open the fan cowl doors (Ref. TASK 71-13-00-010-040): FOR 1000EM1 437AL, 438AR FOR 1000EM2 447AL, 448AR
 (2) put the access platform in position.
 Subtask 26-12-15-865-050

 D. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------49VU ENGINE/2/FIRE DET/LOOP B 8WD2 A07
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(36)