• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:41来源:未知 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 Subtask 26-16-15-865-051
 B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 49VU AIR COND/SDCU/CHAN1 11WQ C06 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 301-399,
 49VU COM/CIDS/DEU B/ESS  153RH G03


 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------**ON A/C 001-049, 051-099, 101-105, 201-299,
 121VU COM NAV/CIDS/DEU B/NORM 162RH M07 R **ON A/C 106-149, 151-199, 401-499,
 121VU COM NAV/CIDS/DEU B/NORM 162RH M08 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 122VU AIR COND/SDCU/CHAN2 12WQ T18 **ON A/C ALL
 4. Procedure
_________
 **ON A/C 001-003,

 (Ref. Fig. 401/TASK 26-16-15-991-001)
 **ON A/C 004-049, 051-099, 101-105, 201-228,

 (Ref. Fig. 401A/TASK 26-16-15-991-001-A)
 **ON A/C 106-149, 229-299,

 (Ref. Fig. 401B/TASK 26-16-15-991-001-D)
 **ON A/C 151-199,

 (Ref. Fig. 401C/TASK 26-16-15-991-001-B)
 **ON A/C 301-302,

 (Ref. Fig. 401D/TASK 26-16-15-991-001-C) **ON A/C 303-399,


 (Ref. Fig. 401E/TASK 26-16-15-991-001-E) R **ON A/C 401-499,
R (Ref. Fig. 401F/TASK 26-16-15-991-001-F) **ON A/C 001-049, 051-061, 101-105, 201-203,
 Subtask 26-16-15-420-050
 A. Installation of the Smoke Detector
 WARNING : DO NOT TRY TO OPEN OR REPAIR THE SMOKE DETECTORS.

_______ THE DETECTOR CONTAINS RADIOACTIVE AMERICIUM 241 OF APPROXIMATELY 0.4 MICROCURIES. ONLY WORKSHOPS AUTHORIZED BY THE MANUFACTURER CAN DO WORK ON THE SMOKE DETECTORS.
 NOTE : The installation procedure is the same for all the smoke
____
 detectors.

 (1)
 Clean the component interface and/or the adjacent area.

 (2)
 Do an inspection of the component interface and/or the adjacent area.

 (3)
 Put the smoke detector (6) in position.

 (4)
 Install the washers (5) and the screws (4).

 (5)
 Remove the blanking caps from the electrical connectors.

 (6)
 Make sure that the electrical connectors are clean and in the correct condition.

 (7)
 Connect the electrical connector (3) to the smoke detector (6).

 (8)
 Put the grid in position (2).

 (9)
 Lock the quick release fasteners (1).


R 1EFF : 001-049, 051-061, 101-105, 201-203, 1 26-16-15Page 416 1303-399, 401-499, 1Aug 01/05 1 1 1CES 1R **ON A/C 062-099, 106-149, 151-199, 204-299, 301-399, 401-499,

 

 Subtask 26-16-15-420-050-A
 A. Installation of the Smoke Detector NOTE : The installation procedure is the same for all the smoke
____
 detectors.

 (1)
 Clean the component interface and/or the adjacent area.

 (2)
 Do an inspection of the component interface and/or the adjacent area.

 (3)
 Put the smoke detector (6) in position.

 (4)
 Install the washers (5) and the screws (4).

 (5)
 Remove the blanking caps from the electrical connectors.

 (6)
 Make sure that the electrical connectors are clean and in the correct condition.

 (7)
 Connect the electrical connector (3) to the smoke detector (6).

 (8)
 Put the grid in position (2).


 (9) Lock the quick release fasteners (1).
 **ON A/C ALL

 Subtask 26-16-15-865-053
 B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s): 11WQ, 12WQ, 153RH, 162RH.
 5. Close-up
________
 Subtask 26-16-15-710-051

 A. Do the operational test of the cargo-compartment smoke-detection system by PTT (Ref. TASK 26-16-00-710-001).


 Subtask 26-16-15-942-051

 B. Remove the ground support and maintenance equipment, the special and standard tools and all other items.


 LAVATORY SMOKE DETECTION - DESCRIPTION AND OPERATION
____________________________________________________
 **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
 1. General
_______ (Ref. Fig. 001) A smoke detection system is installed to detect smoke and/or fire in the lavatories. The lavatory smoke detectors are installed in a loop system, together with the cargo-compartment smoke detectors. If smoke is detected, the system gives a visual and aural warning to the flight crew. This system is made-up of: - one smoke detector for each lavatory,
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(87)