 Remove the protective strip (9) and the band (8) from the smoke detector (1).

 (6)
 Remove and discard the O-rings (3) from the couplings (4).

 (7)
 Put blanking plugs on the couplings (4) and on the openings of the smoke detector (1).


R 1EFF : 001-049, 051-099, 101-105, 151-154, 1 26-15-15Page 402 1201-207, 1May 01/05 1 1 1CES 1


 Smoke Detector
 Figure 401/TASK 26-15-15-991-001
 1EFF :  ALL  1  26-15-15 Page 403 
1  1  Feb 01/98
 1  1
 1CES  1

 


R **ON A/C 106-149, 155-199, 208-299, 301-399, 401-499,
 TASK 26-15-15-000-002
 Removal of the Smoke Detector (1WA) - Avionics Compartment

 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific blanking caps
 No specific blanking plugs
 No specific circuit breaker(s) safety clip(s)
 No specific access platform 1.6 m (5 ft. 3 in.)

 B. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
26-15-15-991-001 Fig. 401
 3. Job Set-up
__________
 Subtask 26-15-15-865-054

 A. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------
PANEL DESIGNATION IDENT. LOCATION
 -------------------------------------------------------------------------------
49VU AIR COND/AVNCS VENT/CTL 5HQ D05
R 1EFF : 106-149, 155-199, 208-299, 301-399, 1 26-15-15Page 404 1401-499, 1Aug 01/05 1 1 1CES 1 Subtask 26-15-15-010-052


 B. Get Access
 (1)
 Put the access platform in position.

 (2)
 Open the access door 824.


 4. Procedure
_________ Subtask 26-15-15-020-051
 A. Removal of the Smoke Detector
 (Ref. Fig. 401/TASK 26-15-15-991-001)

 (1)
 Disconnect the electrical connector (2) from the smoke detector (1).

 (2)
 Put blanking caps on the disconnected electrical connectors.

 (3)
 Hold the smoke detector (1) and loosen the locknut (7) to fully release the clamp (6).

 (4)
 Pull the smoke detector (1) vertically away from the ventilation duct (5).

 (5)
 Remove the protective strip (9) and the band (8) from the smoke detector (1).

 (6)
 Remove and discard the O-rings (3) from the couplings (4).

 (7)
 Put blanking plugs on the couplings (4) and on the openings of the smoke detector (1).


R 1EFF : 106-149, 155-199, 208-299, 301-399, 1 26-15-15Page 405 1401-499, 1Aug 01/05 1 1 1CES 1R **ON A/C 001-049, 051-099, 101-105, 151-154, 201-207,

 

 TASK 26-15-15-400-001
 Installation of the Smoke Detector (1WA) - Avionics Compartment
 WARNING : DO NOT TRY TO OPEN OR REPAIR THE SMOKE DETECTORS.

_______ THE DETECTOR CONTAINS RADIOACTIVE AMERICIUM 241 OF APPROXIMATELY 0.4 MICROCURIES. ONLY WORKSHOPS AUTHORIZED BY THE MANUFACTURER CAN DO WORK ON THE SMOKE DETECTORS.
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------
REFERENCE QTY DESIGNATION
 -------------------------------------------------------------------------------
No specific compressed air
 No specific access platform 1.6 m (5 ft. 3 in.)

 B. Expendable Parts
 -------------------------------------------------------------------------------
FIG.ITEM |DESIGNATION |IPC-CSN
 -------------------------------------------------------------------------------
O-rings 26-15-01 01 -020
 C. Referenced Information
 -------------------------------------------------------------------------------
REFERENCE DESIGNATION
 -------------------------------------------------------------------------------
26-15-00-710-001 Operational Test of the Avionics Smoke Detection 52-41-00-410-002 Close the Avionics Compartment Doors after Access 26-15-15-991-001 Fig. 401
 