__________________
Refer to the MPD TASK: 261200-01
2.
Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------
REFERENCE DESIGNATION
-------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied
from the External Power
31-60-00-860-001 EIS Start Procedure
31-60-00-860-002 EIS Stop Procedure
3. Job Set-up
__________ Subtask 26-12-00-861-050 R A. Energize the aircraft electrical circuits (Ref. TASK 24-41-00-861-002). Subtask 26-12-00-860-050
B. Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).
Subtask 26-12-00-865-050
C. Make sure that this(these) circuit breaker(s) is(are) closed: -------------------------------------------------------------------------------
PANEL ------ DESIGNATION -------------------------------------------------- IDENT. LOCATION-----------------------
49VU ENGINE/2/FIRE DET/LOOP B 8WD2 A07
49VU ENGINE/1/FIRE DET/LOOP A 7WD1 A06
121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/B 2WE1 Q44
121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL1/SQUIB/A 1WE1 Q43
121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/B 2WE2 Q42
121VU ENGINE/ENG1 AND 2 FIRE EXTIG/BTL2/SQUIB/A 1WE2 Q41
121VU ENGINE/ENG2/FIRE DET/LOOP A 7WD2 Q39
121VU ENGINE/ENG1/FIRE DET/LOOP B 8WD1 Q38
4. Procedure_________
Subtask 26-12-00-710-050
A. Do this test
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. On the ENG/APU FIRE panel 1WD:
-push and hold the ENG 1(2) TEST pushbutton switch.
On the ENG/APU FIRE panel 1WD:
- on the ENG 1(2)/FIRE pushbuttonswitch, the FIRE legend comes on.
- on the ENG 1(2)/AGENT 1 and AGENT 2 pushbutton switches, the SQUIB and DISCH legends come on.
On the ENG panel 115VU:
- on the ENG/1(2) FIRE/FAULT annunciator, the FIRE legend comes on.
After some seconds:
-
the continuous repetitive chime operates.
On the F/O and CAPT glareshield panels 130VU and 131VU:
-
the MASTER WARN lights flash.
On the upper ECAM DU:
1EFF : ALL 1 26-12-00Page 502 1 1 May 01/01R 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
2. On the ENG/APU FIRE panel 1WD:
-release the ENG 1(2) TEST pushbutton switch.
5. Close-up
________ Subtask 26-12-00-860-051
A. Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).
Subtask 26-12-00-862-050
-
the ENG 1(2) FIRE warning comes into view.
On the lower ECAM DU:
-
the ENGINE page automatically comes into view.
-all the annunciator lights go off
-the continuous repetitive chime stops - on the upper ECAM DU, the warning goes out of view
- on the lower ECAM DU, the ENGINE page goes out of view.
B. De-energize the aircraft electrical circuits (Ref. TASK 24-41-00-862-002).
1EFF : ALL 1 26-12-00Page 503 1 1 May 01/01R 1 1 1CES 1
TASK 26-12-00-710-002
Operational Test of the Engine Fire and Overheat Detection with the Centralized Fault Display System (CFDS)
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 24-41-00-862-002 De-energize the Aircraft Electrical Circuits Supplied from the External Power 31-32-00-860-005 Procedure to Get Access to the SYSTEM REPORT/TEST FIRE PROT Page
3. Job Set-up
__________
Subtask 26-12-00-861-051
A. Energize the Aircraft Electrical Circuits (Ref. TASK 24-41-00-861-002).
Subtask 26-12-00-869-050
B. On the ENG panel 115VU, make sure that ENG MASTER switches are at OFF.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(28)