• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:41来源:未知 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 **ON A/C 001-049, 051-099, 101-105, 151-154, 201-207,
 7. Operation/Control and Indicating
________________________________
R **ON A/C 106-149, 155-199, 208-299, 301-399, 401-499,
 8. Operation/Control and Indicating
________________________________
 **ON A/C 001-049, 051-099, 101-105, 151-154, 201-207,
 A. Operation
 (Ref. Fig. 008)

 The system includes one self-contained smoke detector of the ionization type with:
 -
a measuring chamber through which the air to be analyzed flows,

 -
a reference resistor.

 


 Smoke Detector - Description
 Figure 006A

R 1EFF : 106-149, 155-199, 208-299, 301-399, 1 26-15-00Page 14 1401-499, 1Aug 01/05 1 1 1CES 1


 Smoke Detector-Operation
 Figure 007

R 1EFF : 106-149, 155-199, 208-299, 301-399, 1 26-15-00Page 15 1401-499, 1Aug 01/05 1 1 1CES 1


 Smoke Detector - Schematic
 Figure 008

R 1EFF : 001-049, 051-099, 101-105, 151-154, 1 26-15-00Page 16 1201-207, 1May 01/05 1 1 1CES 1 Ionization of the measuring chamber is by a source of extremely low radioactivity. When smoke gases go into the detector, they change the balance between the resistor and the ionized chamber and this causes a variation of the detector normal voltage.


 B. Indicating
 When the smoke concentration in the measuring chamber is above the reference threshold, the inner electronic circuit triggers the smoke warnings to the cockpit: (Ref. Fig. 009) - on the EMER ELEC PWR section of the panel 21VU
 . the SMOKE legend of the GEN 1 LINE pushbutton switch comes on,
 - on the VENTILATION section of the OVERHEAD CTL & IND panel 22VU . the FAULT legends of the BLOWER and EXTRACT pusbutton switches come on,
 -the MASTER CAUT light comes on,
 -a warning message is shwon on the lower ECAM display unit.
 The single chime (SC) sounds.
 NOTE : When smoke concentration decreases below the alarm threshold, the
____
 smoke detector returns to the initial state.

R 1EFF : 001-049, 051-099, 101-105, 151-154, 1 26-15-00Page 17 1201-207, 1May 01/05 1 1 1CES 1


 Smoke Detector - Schematic
 Figure 008A

R 1EFF : 106-149, 155-199, 208-299, 301-399, 1 26-15-00Page 18 1401-499, 1Aug 01/05 1 1 1CES 1


 Avionics-Compartment Smoke-Detection System - Indicating and Test

 Figure 009 
R 1EFF : 001-049, 051-099, 101-105, 151-154, 1201-207, 1 1CES  1 111 26-15-00 Page 19 May 01/05

 

 C. Control
 (1) Smoke Procedure
 (Ref. Fig. 010)

 The list of the necessary actions during the smoke procedure comes into view automatically on the lower ECAM display unit while the SMOKE warnings are triggered.
 When these actions are completed, the related lines are cancelled automatically on the lower ECAM display unit (See ATA Ref. 31-51-00).
 The procedure below must be applied:
 (Ref. Fig. 010)

R 1EFF : 001-049, 051-099, 101-105, 151-154, 1 26-15-00Page 20 1201-207, 1May 01/05 1 1 1CES 1


 Avionics-Compartment Smoke-Detection System - Indicating and Test

 Figure 009A 
R 1EFF : 106-149, 155-199, 208-299, 301-399, 1401-499, 1 1CES  1 111 26-15-00 Page 21 Aug 01/05

 

 Avionics-Compartment Smoke-Extraction System - Schematic
 Figure 010

R 1EFF : ALL 1 26-15-00Page 22 1 1 May 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------DISPLAY ACTIONS -------------------------------------------------------------------------------
AVIONICS SMOKE LAND ASAP
 . IF PERCEPTIBLE SMOKE :
 . Smoke from avionics compartment is
 detected directly by the crew.

 -OXY MASK/GOGGLES........ON

 . Make sure crew members can speak to control tower each other. Do not use the interphone position to keep the interference of the oxygen-mask breathing noise to a minimum.
 -CAB FANS...............OFF

 . To keep smoke off the cockpit and the cabin.
 -BLOWER................OVRD

 -EXTRACT...............OVRD

 . Avionics ventilation is provided by air conditioning system and extracted overboard: Valve F opening, valve B partial opening, valves A, E and D closing. Blower fan (A) stopping, extract fan (B) remains energized.
 . IF SMOKE AFTER 5MN00S:
 . An electrical procedure is applied to eliminate the cause of the smoke if the smoke emission persists more than 5 mn.
 -EMERG ELEC GEN 1 LINE..OFF
 . GEN 1 LINE contactor opens. GEN 1 remains in operation and supplies one fuel pump in each wing tank. AC BUS 1 is supplied by GEN 2 through bus tie contactor.
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(60)