R  26-12-00-710-001 Operational Check of Loop/Squib 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 71-13-00-010-040 Opening of the Fan Cowl Doors 71-13-00-410-040 Closing of the Fan Cowl Doors 78-30-00-081-041 Make the Thrust Reverser Serviceable after
 Maintenance
 78-30-00-481-041 Make the Thrust Reverser Unserviceable for

 Maintenance
 78-36-00-010-040 Opening of the Thrust Reverser Doors
 78-36-00-410-040 Closing of the Thrust Reverser Doors
 26-12-16-991-003 Fig. 403

 

R  3. Job Set-up__________ 
R  Subtask 26-12-16-861-051 
R  A. Make sure that the ground service network is energized 
R  (Ref. TASK 24-42-00-861-001). 
R  Subtask 26-12-16-860-053 
R  B. Aircraft Maintenance Configuration 
R  (1) On the center pedestal, on the ENG panel 115VU, make sure that a 
R  warning notice is in position to tell persons not to start the 
R  engine. 
R  (2) On the overhead maintenance panel 50VU, make sure that the ON legend 
R  of the ENG/FADEC GND PWR/1(2) is off. Make sure that a warning notice 
R  is in position to tell persons not to energize the FADEC 1(2). 
R  (3) Make sure that the access platform is in position. 
R  Subtask 26-12-16-010-056 
R  C. Get Access 
R  (1) Make sure that the fan cowl doors are open: (Ref. TASK 71-13-00-010-
R  040) 
R  FOR 1000EM1 
R  437AL, 438AR 
R  FOR 1000EM2 
R  447AL, 448AR 
R  (2) Make sure that the thrust reverser doors are open: (Ref. TASK 78-36-
R  00-010-040) 
R  FOR 1000EM1 
R  451AL, 452AR 
R  FOR 1000EM2 
R  461AL, 462AR

 

R Subtask 26-12-16-865-054

R  D. Make sure that this(these) circuit breaker(s) is(are) open, safetied and 
R  tagged 
R  -------------------------------------------------------------------------------
R  PANEL DESIGNATION IDENT. LOCATION 
R  -------------------------------------------------------------------------------
R  FOR 1000EM1 
R  49VU ENGINE/1/FIRE DET/LOOP A 7WD1 A06 
R  121VU ENGINE/ENG1/FIRE DET/LOOP B 8WD1 Q38 
R  FOR 1000EM2 
R  49VU ENGINE/2/FIRE DET/LOOP B 8WD2 A07 
R  121VU ENGINE/ENG2/FIRE DET/LOOP A 7WD2 Q39 
R  Subtask 26-12-16-040-053 
R  E. Make sure that the thrust reverser is unserviceable (Ref. TASK 78-30-00-
R  481-041). 
R  4. Procedure_________ 
R  (Ref. Fig. 403/TASK 26-12-16-991-003) 
R  Subtask 26-12-16-420-052 
R  A. Installation of the Support Assembly 
R  (1) Put the support assembly (7) in position. 
R  (2) Install the bolts (5) and nuts (4) to the support but do not tighten 
R  at this time. 
R  (3) Install the clamps (3), washers (6), bolts (2), and the nuts (1) to 
R  the support but do not tighten at this time. 
R  (4) Tighten the bolts (2) and (5). 
R  (5) Remove the blanking caps from the electrical connectors. 
R  (6) Connect the electrical connectors to the fire detectors. 
R  Subtask 26-12-16-865-055 
R  B. Remove the safety clip(s) and the tag(s) and close this(these) circuit 
R  breaker(s): 
R  7WD1, 7WD2, 8WD1, 8WD2.

 

R Subtask 26-12-16-860-054

R  C. Do the EIS start procedure (Upper ECAM only) (Ref. TASK 31-60-00-860-
R  001). 
R  Subtask 26-12-16-710-051 
R  D. Do this test. 
R  (1) On the upper DU, make sure that the FIRE ENG1(2) LOOP A (B) FAULT 
R  message has gone out of view. 
R  (2) Do an operational test of the engine fire detection system (Ref. TASK 
R  26-12-00-710-001). 
R  Subtask 26-12-16-860-055 
R  E. Do the EIS stop procedure: (Ref. TASK 31-60-00-860-002). 
R  5. Close-up________ 
R  Subtask 26-12-16-410-052 
R  A. Close Access 
R  (1) Make sure that the work area is clean and clear of tool(s) and other 
R  items. 
R  (2) Close the thrust reverser doors: (Ref. TASK 78-36-00-410-040) 
R  FOR 1000EM1 
R  451AL, 452AR 
R  FOR 1000EM2 
R  461AL, 462AR 
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(45)