ACTION RESULT
-------------------------------------------------------------------------------
R All warnings and indications are
R cancelled.
R **ON A/C 106-149, 301-399, 401-499,
R Subtask 26-16-00-710-050-D
R A. Test of the Cargo-Compartment Smoke-Detection System
R (1) Both CIDS-SDF channels and all cargo-compartment smoke-detectors must
R be supplied with power for a minimum of 30 seconds before you start
R the test.
R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------
R 1. On the CARGO SMOKE panel 22VU: On the CARGO SMOKE panel 22VU:
R - Push and hold the TEST - The FWD DISCH and the AFT DISCH
R pushbutton switch approx. 20 indication lights come on.
R seconds.
R On the glareshield panels 130VU and
R 131VU:
R - The MASTER WARN lights flash.
R - The continuous repetitive chime (CRC)
R operates.
R
R On the ECAM upper display unit:
R - SMOKE FWD CARGO SMOKE
R - ......AFT CARGO SMOKE
R - ...AFT ISOL VALVE...OFF
R come on.
R
R On the CARGO SMOKE panel 22VU:
R - The FWD SMOKE and the AFT SMOKE
R indication lights come on.
R
R On the ECAM upper display unit:
R - ...AFT ISOL VALVE...OFF
R 1EFF : 004-049, 051-099, 101-149, 151-199, 1 26-16-00Page 509 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R goes off.
R
R On the ECAM lower display unit:
R - The AFT cargo-compartment
R isolation-valve symbols close.
R
R - Release the TEST pushbutton On the CARGO SMOKE panel 22VU:
R switch. - The FWD DISCH and the AFT DISCH
R indication lights go off.
R
R On the ECAM lower display unit:
R - The AFT cargo-compartment
R isolation-valve symbols open.
R
R On the ECAM upper display unit:
R - ...AGENT...........DISCH
R - ...AGENT...........DISCH
R also come on.
R
R On the ECAM upper display unit:
R - SMOKE FWD CARGO SMOKE
R - ...AGENT...........DISCH
R - ......AFT CARGO SMOKE
R - ...AGENT...........DISCH
R go off.
R
R On the glareshield panels 130VU and
R 131VU:
R - The MASTER WARN lights go off.
R - The continuous repetitive chime
R stops.
R
R On the CARGO SMOKE panel 22VU:
R - The FWD SMOKE and the AFT SMOKE
R indication lights go off.
R
R 1EFF : 106-149, 301-399, 401-499, 1 26-16-00Page 510 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R On the glareshield panels 130VU and
R 131VU:
R - The MASTER WARN lights flash.
R - The continuous repetitive chime
R operates.
R
R On the ECAM upper display unit:
R - SMOKE FWD CARGO SMOKE
R - ...AGENT...........DISCH
R - ......AFT CARGO SMOKE
R - ...AFT ISOL VALVE...OFF
R - ...AGENT...........DISCH
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(77)