FIRE DETECTION UNIT (FDU) - APU (13WG) - REMOVAL/INSTALLATION
_____________________________________________________________
TASK 26-13-34-000-001
Removal of the APU Fire-Detection Unit (FDU) (13WG)
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
No specific warning notice
No specific access platform 1.6 m (5 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
26-13-34-991-001 Fig. 401
3. Job Set-up
__________ Subtask 26-13-34-865-050
A. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/FIRE AND OVHT/DET/LOOP B 2WG L44 121VU APU/FIRE AND OVHT/DET/LOOP A 1WG L43
Subtask 26-13-34-941-050
B. Safety Precautions
(1) In the cockpit, on the OVERHEAD CTL & IND panel 25VU, put a warning notice to tell the persons not to start the APU .
Subtask 26-13-34-010-050
C. Get Access
(1)
Put the access platform in position.
(2)
Open the access door 824.
4. Procedure
_________
(Ref. Fig. 401/TASK 26-13-34-991-001) Subtask 26-13-34-020-050
A. Remove the APU Fire Detection Unit (FDU):
(1)
Disconnect the electrical connectors (5) and (6) from the Fire Detection Unit (1)
(2)
Put blanking caps on the electrical connectors (5) and (6).
(3)
Remove the screws (2) and the washers (3).
(4)
Remove the fire detection unit (1)
APU Fire-Detection Unit
Figure 401/TASK 26-13-34-991-001
1EFF : ALL 1 26-13-34 Page 403
1 1 Feb 01/98
1 1
1CES 1
TASK 26-13-34-400-001
Installation of the APU Fire-Detection Unit (FDU) (13WG)
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
No specific warning notice
No specific access platform 1.6 m (5 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
R 26-13-00-710-001 Operational Test of the APU Fire and Overheat R Detection System 31-32-00-860-005 Procedure to Get Access to the SYSTEM REPORT/TEST
FIRE PROT Page 31-60-00-860-001 EIS Start Procedure 31-60-00-860-002 EIS Stop Procedure 52-41-00-410-002 Close the Avionics Compartment Doors after Access 26-13-34-991-001 Fig. 401
3. Job Set-up
__________
Subtask 26-13-34-860-050
A. In the cockpit, on the OVERHEAD CTL & IND panel 25VU, make sure that the warning notice is in position to tell persons not to start the APU.
Subtask 26-13-34-010-051
B. Get Access
(1) Make sure that access platform is in position.
(2) Make sure that the access door 824 is open. Subtask 26-13-34-865-051
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/FIRE AND OVHT/DET/LOOP B 2WG L44 121VU APU/FIRE AND OVHT/DET/LOOP A 1WG L43