-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R - push the line key adjacent to - the SMOKE WARNING TESTS menu comes
R the SMOKE WARN TESTS on.
R indication.
R - push the line key adjacent to - the SMOKE DET LAVATORY TESTS menu
R the SMOKE DET LAVATORY TESTS comes on.
R indication.
R - push the line key adjacent to - the SMK DET LAV X TEST page comes on
R the SMK DET LAV X TEST and shows:
R indication. ON ECAM WARNING DISPLAY
R MAKE SURE THAT
R "SMOKE LAVATORY" IS
R INDICATED
R On the glareshield panels 130VU and
R 131VU:
R - the MASTER WARN lights flash.
R - the Associated Triple Chime comes on.
R On the ECAM upper display unit:
R - SMOKE LAVATORY SMOKE comes on.
R - push the line key adjacent to On the MCDU:
R the YES indication. - the SMK DET LAV X TEST page shows:
R IN THE CABIN MAKE SURE
R THAT "SMOKE LAV #" IS
R INDICATED ON THE FAP/AIP
R On the FAP:
R - the indication SMOKE DETECTED
R together with the location-indication
R LAV X comes on.
R On the related lavatory:
R - the amber lavatory CALL light
R flashes.
R On the Area Call Panel (ACP) nearest to
R the related lavatory:
R - the amber light flashes.
R On the Attendant Indication Panels
R (AIPs):
-------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
R - SMOKE LAVATORY X is shown and the red
R light flashes.
R 2. On the FAP or the related AAP: On the related lavatory:
R - push the SMOKE RESET key. - the amber CALL light goes off.
R In the cabin:
R - the LAVATORY SMOKE chime stops.
R On the AIPs:
R - SMOKE LAV X and the red light go off.
R On the ACP nearest to the related
R lavatory:
R - the amber light goes off.
R
R On the MCDU: On the MCDU:
R - push the line key adjacent to - the SMK DET LAV X TEST page shows:
R the YES indication. TEST OK
R 3. On the MCDU: On the MCDU:
R - push the line key adjacent to - the SMK DET LAVATORY TESTS menu comes
R the RETURN indication. on.
R
R After approx. 5 seconds:
R
R On the glareshield panels 130VU and
R 131VU:
R - the MASTER WARN lights go off.
R - the Associated Triple Chime stops.
R On the ECAM upper display unit:
R - SMOKE LAVATORY SMOKE goes off.
R On the FAP:
R - the indications SMOKE DETECTED and
R LAV X go off.
R
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R 4. Do the test again for the smoke
R detectors of all the other
R lavatories.
R **ON A/C ALL
R 5. Close-up________
R Subtask 26-17-00-860-051
R A. Put the aircraft back to its initial configuration.
R (1) On the MCDU, push the line key adjacent to the RETURN indication
R until the CFDS menu page comes into view.
R (2) Do the EIS stop procedure
R (Ref. TASK 31-60-00-860-002)
R (3) De-energize the aircraft electrical circuits
R (Ref. TASK 24-41-00-862-002).
R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
TASK 26-17-00-720-001
Functional Test of the Lavatory Smoke-Detector Sensitivity
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(94)