 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R  - push the line key adjacent to  - the SMOKE WARNING TESTS menu comes 
R  the SMOKE WARN TESTS  on. 
R  indication. 
R  - push the line key adjacent to  - the SMOKE DET LAVATORY TESTS menu 
R  the SMOKE DET LAVATORY TESTS  comes on. 
R  indication. 
R  - push the line key adjacent to  - the SMK DET LAV X TEST page comes on 
R  the SMK DET LAV X TEST  and shows: 
R  indication.  ON ECAM WARNING DISPLAY 
R  MAKE SURE THAT 
R  "SMOKE LAVATORY" IS 
R  INDICATED 
R  On the glareshield panels 130VU and 
R  131VU: 
R  - the MASTER WARN lights flash. 
R  - the Associated Triple Chime comes on. 
R  On the ECAM upper display unit: 
R  - SMOKE LAVATORY SMOKE comes on. 
R  - push the line key adjacent to  On the MCDU: 
R  the YES indication.  - the SMK DET LAV X TEST page shows: 
R  IN THE CABIN MAKE SURE 
R  THAT "SMOKE LAV #" IS 
R  INDICATED ON THE FAP/AIP 
R  On the FAP: 
R  - the indication SMOKE DETECTED 
R  together with the location-indication 
R  LAV X comes on. 
R  On the related lavatory: 
R  - the amber lavatory CALL light 
R  flashes. 
R  On the Area Call Panel (ACP) nearest to 
R  the related lavatory: 
R  - the amber light flashes. 
R  On the Attendant Indication Panels 
R  (AIPs):

 

 -------------------------------------------------------------------------------
ACTION RESULT -------------------------------------------------------------------------------
R  - SMOKE LAVATORY X is shown and the red 
R  light flashes. 
R  2. On the FAP or the related AAP:  On the related lavatory: 
R  - push the SMOKE RESET key.  - the amber CALL light goes off. 
R  In the cabin: 
R  - the LAVATORY SMOKE chime stops. 
R  On the AIPs: 
R  - SMOKE LAV X and the red light go off. 
R  On the ACP nearest to the related 
R  lavatory: 
R  - the amber light goes off. 

R  On the MCDU:  On the MCDU: 
R  - push the line key adjacent to  - the SMK DET LAV X TEST page shows: 
R  the YES indication.  TEST OK 
R  3. On the MCDU:  On the MCDU: 
R  - push the line key adjacent to  - the SMK DET LAVATORY TESTS menu comes 
R  the RETURN indication.  on. 

R  After approx. 5 seconds: 

R  On the glareshield panels 130VU and 
R  131VU: 
R  - the MASTER WARN lights go off. 
R  - the Associated Triple Chime stops. 
R  On the ECAM upper display unit: 
R  - SMOKE LAVATORY SMOKE goes off. 
R  On the FAP: 
R  - the indications SMOKE DETECTED and 
R  LAV X go off. 
R

 

 -------------------------------------------------------------------------------
ACTION  RESULT
 -------------------------------------------------------------------------------
R  4. Do the test again for the smoke 
R  detectors of all the other 
R  lavatories. 
R  **ON A/C ALL 
R  5. Close-up________ 
R  Subtask 26-17-00-860-051 
R  A. Put the aircraft back to its initial configuration. 
R  (1) On the MCDU, push the line key adjacent to the RETURN indication 
R  until the CFDS menu page comes into view. 
R  (2) Do the EIS stop procedure 
R  (Ref. TASK 31-60-00-860-002) 
R  (3) De-energize the aircraft electrical circuits 
R  (Ref. TASK 24-41-00-862-002).

 


R **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,

 TASK 26-17-00-720-001
 Functional Test of the Lavatory Smoke-Detector Sensitivity
 1. Reason for the Job
__________________
 Self Explanatory
 2. Job Set-up Information
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(94)