NOTE : The end of each fire detector (45) sensor tube may be set
____
R R in a loop. Do not allow more than 1 in. (25.40 mm) overhang from the liner at the end locations.
(j) TORQUE the bolts (50) to between 20 and 25 lbf.in (0.22 and 0.28 m.daN).
(k) Connect the electrical connectors 4000WD1A and 4000WD2A to the fire detectors (45). Tighten the connectors by hand and lock them by one-eighth turn.
Subtask 26-12-15-865-070
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breakers(s): 7WD1, 7WD2, 8WD1, 8WD2 7WD1, 7WD2, 8WD1, 8WD2
Subtask 26-12-15-860-072
C. Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) (Ref. TASK 31-60-00-860-001).
Subtask 26-12-15-710-056
D. Do this test.
R R (1) On the upper ECAM DU, make sure that the FIRE ENG1(2) LOOP A (B) FAULT message went out of view.
(2) Do an operational test of the engine fire and overheat detection (Loop/Squib) (Ref. TASK 26-12-00-710-001).
5. Close-up________
Subtask 26-12-15-860-073
A. Do the EIS stop procedure (Ref. TASK 31-60-00-860-002).
Subtask 26-12-15-410-057
B. Close Access
(1) Make sure that the work area is clean and clear of tool(s) and other items.
(2) Close the fan cowl doors (Ref. TASK 71-13-00-410-040): FOR 1000EM1 R 437AL, 438AR
FOR 1000EM2 R 447AL, 448AR.
(3) Remove the warning notice(s).
(4) Remove the access platform(s).
Subtask 26-12-15-862-056
C. De-energize the ground service network (Ref. TASK 24-42-00-862-001).
DETECTOR - FIRE, PYLON (LOOP A AND B) (3WD1,3WD2,4WD1,4WD2)
___________________________________________________________ REMOVAL/INSTALLATION
____________________
TASK 26-12-16-000-001
Removal of the Pylon Fire Detectors (3WD1,3WD2,4WD1,4WD2)
WARNING : BE CAREFUL WHEN YOU WORK ON THE ENGINE COMPONENTS IMMEDIATELY AFTER
_______ THE ENGINE IS SHUTDOWN. THE ENGINE COMPONENTS CAN STAY HOT FOR UP TO ONE HOUR.
1. Reason for the Job
__________________
Self Explanatory
2. Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
No specific warning notice
No specific access platform 1 m (3 ft. 3 in.)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
26-12-16-000-002 Removal of the Support with the Pylon Fire Detectors 71-13-00-010-040 Opening of the Fan Cowl Doors 78-30-00-481-041 Make the Thrust Reverser Unserviceable for
Maintenance
78-36-00-010-040 Opening of the Thrust Reverser Doors
26-12-16-991-001 Fig. 401