__________
4.
Procedure
_________ Subtask 26-17-15-750-050
A. Special test of the Lavatory Smoke Detector NOTE : The test procedure is the same for all lavatory smoke detectors.
____
(1)
Make sure that the outflow valve at the RH AFT lower fuselage is open.
(2)
Make sure that the lavatory/galley extraction fan operates.
(3)
Use an approved smoke generation kit for this test (We recommend ventilation smoke tubes).
R 1EFF : ALL 1 26-17-15Page 426 1 1 May 01/05 1 1 1CES 1 (4) Do this test.
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1. In the lavatory:
-apply the smoke source adjacent to the lavatory smoke detector.
2. Close the lavatory door.
R R
R R
3. On the FWD Attendant Panel (FAP) 120RH:
In the cockpit and in the cabin:
-the lavatory smoke warning must come on in less than 1 min (usual 15 to 40 seconds).
NOTE : If a malfunction occurs refer to
____ para 4.C.
On the glareshield panels 130VU and 131VU:
-the MASTER WARNING lights flash.
-an associated triple chime, repeated every 30 seconds is heard.
On the ECAM upper display unit:
-the message SMOKE LAVATORY SMOKE comes on.
At all attendant stations and from all cabin loudspeakers:
-
an associated triple chime, repeated every 30 seconds is heard.
On the nearest Area Call Panel (ACP):
-
an amber light flashes.
On all Attendant Indication Panels (AIP):
-
the message SMOKE LAV A is shown and a red light comes on.
On the FWD Attendant Panel (FAP) 120RH:
-
the red indicator light LAV SMOKE comes on (effect for all lavatories).
In the cabin and on the FWD AttendantPanel (FAP) 120RH:
R 1EFF : ALL 1 26-17-15Page 427 1 1 May 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
- push the RESET pushbutton switch. - all cabin warnings are cancelledexcept the red indicator light LAV SMOKE.
R 4. On the ECAM control panel 11VU: - push the EMERGENCY CANCEL pushbutton switch. In the cockpit: - the associated triple chime stops.
On the glareshield panels 130VU and 131VU:
- the MASTER WARNING lights go off.
On the ECAM upper display unit: - the message SMOKE LAVATORY SMOKE goes off.
On the FWD Attendant Panel (FAP) 120RH: - the red indicator light LAV SMOKE goes off after some time.
(5)
If the lavatory smoke warning does not come on in this time limit, clean the smoke detector ducts (Ref. TASK 26-17-15-100-002).
(6)
Do the test procedure steps A1 to A4 again.
5. Close-up
________R **ON A/C 004-049, 053-099, 101-149, 151-199, 201-299, 301-399, 401-499,
TASK 26-17-15-000-008
Removal of the Lavatory Smoke Detector (2WQ/4WQ/5WQ/6WQ/8WQ/9WQ/14WQ/15WQ)
1.
Reason for the Job
__________________
Self Explanatory
2.
Job Set-up Information
______________________
A. Fixtures, Tools, Test and Support Equipment
-------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
No specific blanking caps
No specific circuit breaker(s) safety clip(s)
B. Referenced Information
-------------------------------------------------------------------------------REFERENCE DESIGNATION -------------------------------------------------------------------------------
24-41-00-861-002 Energize the Aircraft Electrical Circuits from the External Power 26-17-15-991-017 Fig. 404
3. Job Set-up
__________
Subtask 26-17-15-861-060
A. Energize the aircraft electrical circuits
(Ref. TASK 24-41-00-861-002)
R 1EFF : 004-049, 053-099, 101-149, 151-199, 1 26-17-15Page 429 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
Subtask 26-17-15-865-086
B. Open, safety and tag this(these) circuit breaker(s):
-------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------