R  Subtask 26-17-00-710-050-A 
R  A. Test of the Lavatory Smoke-Detection System 
R  -------------------------------------------------------------------------------
R  ACTION  RESULT 
R  -------------------------------------------------------------------------------

R  1. On the MCDU:  On the MCDU: 
R  - push the line key adjacent to  - the SDCU page comes on. 
R  the SDCU indication. 
R  On the MCDU:  On the MCDU: 
R  - push the line key adjacent to  - the SDCU/TEST/MENU page comes on. 
R  the TEST indication. 
R  2. On the MCDU:  On the MCDU: 
R  - push the line key adjacent to  - SMOKE DET LAV DD (xx) is shown. 
R  the first SMOKE DET LAV DD 
R  (xx).  - the TEST WAIT message ist shown. 
R  After approx. 5 seconds. 

R  - the SDCU/TEST/REPORT page comes on 
R  and shows: 
R  SMOKE DET LAV DD (xx) 
R  TEST OK 
R  CK ECAM AND CABIN WARN. 
R  NOTE : DD shows the related lavatory____ 
R  location. xx shows the related 
R  FIN number. 
R  On the glareshield panels 130VU and 
R  131VU: 
R  - the MASTER WARN lights flash. 
R  - the Continuous Repetitive Chime (CRC) 
R  is heard. 

R 1EFF : ALL 1 26-17-00Page 504 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------
ACTION  RESULT
 -------------------------------------------------------------------------------
R  On the Engine/Warning Display (EWD): 
R  - SMOKE LAVATORY SMOKE is shown. 
R  In the cabin: 
R  - the LAVATORY SMOKE chime is heard. 
R  On the related lavatory: 
R  - the yellow lavatory CALL light 
R  flashes. 
R  On the Area Call Panel (ACP) nearest to 
R  the related lavatory: 
R  - the yellow light flashes. 
R  On the Attendant Indication Panels 
R  (AIP事s): 
R  - SMOKE LAVATORY DD is shown and the 
R  red light flashes. 
R  On the Forward Attendant Panel (FAP) or 
R  the related Additional Attendant Panel 
R  (AAP): 
R  - the red indicator light SMOKE LAV 
R  comes on. 

R  3. On the FAP or the related AAP:  On the related lavatory: 
R  - push the LAV SMOKE/RESET  - the yellow CALL light goes off. 
R  pushbutton switch. 
R  In the cabin: 
R  - the LAVATORY SMOKE chime stops. 
R  On the AIP事s: 
R  - SMOKE LAV DD and the red light goes 
R  off. 
R  On the ACP nearest to the related 
R  lavatory: 
R  - the yellow light goes off. 

R  4. On the MCDU:  On the MCDU: 

R 1EFF : 001-049, 051-061, 101-105, 1 26-17-00Page 505 1 1 Aug 01/05 1 1 1CES 1


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R  - push the line key adjacent to  - the SDCU/TEST/MENU page comes on. 
R  the RETURN indication. 
R  After approx. 5 seconds. 

R  On the glareshield panels 130VU and 
R  131VU: 
R  - the MASTER WARN lights go off. 
R  - the CRC stops. 
R  On the EWD: 
R  - SMOKE LAVATORY SMOKE goes off. 
R  On the FAP or the related AAP: 
R  - the red LAV SMOKE light goes off. 

R  5. Do the test again for the smoke 
R  detectors of all the other 
R  lavatories. 

R  NOTE : If necessary, on the MCDU____ 
R  push the NEXT PAGE 
R  pushbutton switch to show 
R  the smoke detectors of the 
R  other lavatories. 

R 1EFF : 001-049, 051-061, 101-105, 1 26-17-00Page 506 1 1 Aug 01/05 1 1 1CES 1


R  **ON A/C 062-099, 151-199, 201-299, 
R  Subtask 26-17-00-710-050-B 
R  A. Test of the Lavatory Smoke-Detection System 
R  -------------------------------------------------------------------------------
 