R 1. On the MCDU: On the MCDU:
R - push the line key adjacent to - the SDCU page comes on.
R the SDCU indication.
R On the MCDU: On the MCDU:
R - push the line key adjacent to - the SDCU/TEST/MENU page comes on.
R the TEST indication.
R 2. On the MCDU: On the MCDU:
R - push the line key adjacent to - SMOKE DET LAV DD (xx) is shown.
R the first SMOKE DET LAV DD
R (xx). - the TEST WAIT message ist shown.
R After approx. 5 seconds.
R
R - the SDCU/TEST/REPORT page comes on
R and shows:
R SMOKE DET LAV DD (xx)
R TEST OK
R CK ECAM AND CABIN WARN.
R NOTE : DD shows the related lavatory____
R location. xx shows the related
R FIN number.
R On the glareshield panels 130VU and
R 131VU:
R - the MASTER WARN lights flash.
R - the Continuous Repetitive Chime (CRC)
R is heard.
R On the Engine/Warning Display (EWD):
R - SMOKE LAVATORY SMOKE is shown.
R In the cabin:
R - the LAVATORY SMOKE chime is heard.
R 1EFF : 062-099, 151-199, 201-299, 1 26-17-00Page 507 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R On the related lavatory:
R - the amber lavatory CALL light
R flashes.
R On the Area Call Panel (ACP) nearest to
R the related lavatory:
R - the amber light flashes.
R On the Attendant Indication Panels
R (AIPs):
R - SMOKE LAVATORY DD is shown and the
R red light flashes.
R On the Forward Attendant Panel (FAP) or
R the related Additional Attendant Panel
R (AAP):
R - the red indicator light SMOKE LAV
R comes on.
R
R 3. On the FAP or the related AAP: On the related lavatory:
R - push the LAV SMOKE/RESET - the amber CALL light goes off.
R pushbutton switch.
R In the cabin:
R - the LAVATORY SMOKE chime stops.
R On the AIPs:
R - SMOKE LAV DD and the red light goes
R off.
R On the ACP nearest to the related
R lavatory:
R - the amber light goes off.
R
R 4. On the MCDU: On the MCDU:
R - push the line key adjacent to - the SDCU/TEST/MENU page comes on.
R the RETURN indication.
R After approx. 5 seconds.
R
R 1EFF : 062-099, 151-199, 201-299, 1 26-17-00Page 508 1 1 Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
R R R R ACTION RESULT -------------------------------------------------------------------------------On the glareshield panels 130VU and 131VU: - the MASTER WARN lights go off. - the CRC stops.
R R On the EWD: - SMOKE LAVATORY SMOKE goes off.
R R R On the FAP or the related AAP: - the red LAV SMOKE light goes off.
R R R R 5. Do the test again for the smoke detectors of all the other lavatories.
R R R R R NOTE : If necessary, on the MCDU____ push the NEXT PAGE pushbutton switch to show the smoke detectors of the other lavatories.
R **ON A/C 106-149, 301-399, 401-499,
R Subtask 26-17-00-710-050-D
R A. Test of the Lavatory Smoke-Detection System
R R R -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R 1. On the MCDU: On the MCDU
R - push the line key adjacent to - the CIDS-SDF1 page comes on and
R the SDCU indication. shows:
R SDCU FUNCTION
R IS INTEGRATED IN
R CIDS DIRECTORS
R 101RH & 102RH
R CALLED CIDS-SDFx
R - push the NEXT PAGE button. - the CIDS-SDF1 main menu comes on.