PANEL DESIGNATION IDENT. LOCATION
-------------------------------------------------------------------------------
R **ON A/C 106-149, 151-199, 401-499,
R R 121VU COM NAV/CIDS/DIR NORM/2 **ON A/C 301-399, 156RH M06
R R R 121VU COM NAV/CIDS/DIR NORM/2 156RH 121VU COM NAV/CIDS/DIR NORM/1 151RH **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, M07 M06
R R 122VU AIR COND/AFT CARGO VENT/FAN **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 30HN S22
R R 122VU AIR COND/SDCU/CHAN2 **ON A/C 001-049, 051-099, 101-149, 151-199, 201-299, 301-399, 12WQ T18
R R R R R 122VU AIR COND/ZONE TEMP CTL/28VDC/SYS2 4HK 122VU AIR COND/ZONE TEMP CTL/28VDC/SYS1 3HK 122VU AIR COND/ZONE TEMP CTL/115VAC/SYS2 2HK 122VU AIR COND/ZONE TEMP CTL/115VAC/SYS1 1HK **ON A/C 004-049, 051-099, 101-149, 151-199, 201-299, 301-399, 401-499, V20 V19 V18 V17
R R 122VU AIR COND/CARGO/FIRE/EXTIG **ON A/C 106-149, 301-399, 401-499, 1WX T19
R R 122VU AIR COND/CIDS/SDF/DIR NORM/2 122VU AIR COND/CIDS/SDF/DIR NORM/1 14WH 17WH T18 T17
R **ON A/C ALL
R Subtask 26-16-00-865-059
R C. Make sure that this(these) circuit breaker(s) is(are) closed:
R -------------------------------------------------------------------------------
R PANEL DESIGNATION FIN LOCATION
R -------------------------------------------------------------------------------
R 122VU AIR COND/AFT CARGO VENT/CTL AND/MONG 31HN 20 S
R or alternative location :-
R 49VU AIR COND/AFT CARGO/VENT/CTL & MONG 31HN 07 C
R 4. Procedure_________
R **ON A/C 001-003,
R Subtask 26-16-00-710-050-B
R A. Test of the Cargo-Compartment Smoke-Detection System
R NOTE : Make sure that the SDCU is supplied with power for at least one____
R minute before you start the test.
R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------
R 1. On the CARGO SMOKE panel 22VU: On the glareshield panels 130VU and
R - push and hold the TEST 131VU:
R pushbutton switch approx. 20 - the MASTER WARN lights flash and a
R seconds. continuous repetitive chime is heard.
R
R On the ECAM upper display unit:
R - SMOKE AFT CARGO SMOKE
R - ...AFT ISOL VALVE...OFF
R come on.
R
R On the CARGO SMOKE panel 22VU:
R - the AFT SMOKE indication light comes
R on.
R
-------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
R On the ECAM upper display unit:
R - ...AFT ISOL VALVE...OFF
R goes off.
R
R On the ECAM lower display unit:
R - the AFT cargo-compartment
R isolation-valve symbols close.
R
R - release the TEST pushbutton On the ECAM lower display unit:
R switch. - the AFT cargo-compartment
R isolation-valve symbols open.
R
R On the ECAM upper display unit:
R - SMOKE AFT CARGO SMOKE
R comes on.
R On the ECAM upper display unit:
R - SMOKE AFT CARGO SMOKE
R goes off.
R
R On the glareshield panels 130VU and
R 131VU:
R - the MASTER WARN lights go off.
R - the continuous repetitive chime is
R cancelled.
R
R On the CARGO SMOKE panel 22VU:
R - the AFT SMOKE indication light goes
R off.
R
R On the glareshield panels 130VU and
R 131VU:
R - the MASTER WARN lights flash and a
R continuous repetitive chime is heard.
R
R On the ECAM upper display unit:
R - SMOKE AFT CARGO SMOKE
R 1EFF : 001-003, 1 26-16-00Page 505 1 1 Aug 01/05 1 1 1CES 1 中国航空网 www.aero.cn 航空翻译 www.aviation.cn 本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(75)