ACTION RESULT
-------------------------------------------------------------------------------
R - ...AFT ISOL VALVE...OFF
R come on.
R
R On the ECAM lower display unit:
R - on the COND page, the AFT
R cargo-compartment isolation-valve
R symbols show open.
R
R On the CARGO SMOKE panel 22VU:
R - the AFT SMOKE indication light comes
R on.
R
R After approx. 15 seconds:
R All warnings and indications are
R cancelled.
R **ON A/C 004-049, 051-099, 101-105, 151-199, 201-299,
R Subtask 26-16-00-710-050-A
R A. Test of the Cargo-Compartment Smoke-Detection System
R NOTE : Make sure that the SDCU is supplied with power for at least one____
R minute before you start the test.
R -------------------------------------------------------------------------------
R ACTION RESULT
R -------------------------------------------------------------------------------
R 1. On the CARGO SMOKE panel 22VU: On the CARGO SMOKE panel 22VU:
R - push and hold the TEST - the FWD DISCH and the AFT DISCH
R pushbutton switch approx. 20 indication lights come on.
R seconds.
R On the glareshield panels 130VU and
R 131VU:
R - the MASTER WARN lights flash and a
R continuous repetitive chime is heard.
R
R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 26-16-00Page 506 1201-299, 1Aug 01/05 1 1 1CES 1
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R On the ECAM upper display unit:
R - SMOKE FWD CARGO SMOKE
R - ......AFT CARGO SMOKE
R - ...AFT ISOL VALVE...OFF
R come on.
R
R On the CARGO SMOKE panel 22VU:
R - the FWD SMOKE and the AFT SMOKE
R indication lights come on.
R
R On the ECAM upper display unit:
R - ...AFT ISOL VALVE...OFF
R goes off.
R
R On the ECAM lower display unit:
R - the AFT cargo-compartment
R isolation-valve symbols close.
R
R - release the TEST pushbutton On the CARGO SMOKE panel 22VU:
R switch. - the FWD DISCH and the AFT DISCH
R indication lights go off.
R
R On the ECAM lower display unit:
R - the AFT cargo-compartment
R isolation-valve symbols open.
R
R On the ECAM upper display unit:
R - SMOKE FWD CARGO SMOKE
R - ...AGENT...........DISCH
R - ......AFT CARGO SMOKE
R - ...AGENT...........DISCH
R come on.
R
R On the ECAM upper display unit:
R - SMOKE FWD CARGO SMOKE
R - ...AGENT...........DISCH
R - ......AFT CARGO SMOKE
-------------------------------------------------------------------------------
ACTION RESULT
-------------------------------------------------------------------------------
R - ...AGENT...........DISCH
R go off.
R
R On the glareshield panels 130VU and
R 131VU:
R - the MASTER WARN lights go off.
R - the continuous repetitive chime is
R cancelled.
R
R On the CARGO SMOKE panel 22VU:
R - the FWD SMOKE and the AFT SMOKE
R indication lights go off.
R
R On the glareshield panels 130VU and
R 131VU:
R - the MASTER WARN lights flash and a
R continuous repetitive chime is heard.
R
R On the ECAM upper display unit:
R - SMOKE FWD CARGO SMOKE
R - ...AGENT...........DISCH
R - ......AFT CARGO SMOKE
R - ...AFT ISOL VALVE...OFF
R - ...AGENT...........DISCH
R come on.
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(76)