• 热门标签

当前位置: 主页 > 航空资料 > 机务资料 >

时间:2011-03-21 08:41来源:未知 作者:admin
曝光台 注意防骗 网曝天猫店富美金盛家居专营店坑蒙拐骗欺诈消费者

 from the External Power 31-60-00-860-001 EIS Start Procedure 33-14-00-710-001 Operational Test of the Annunciator Light Test System
 in the Cockpit
 3. Job Set-up
__________ Subtask 26-13-00-860-050
 A. Aircraft Maintenance Configuration
 (1)
 Energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-861-002).


 (2)
 Energize the ECAM system (Ref. TASK 31-60-00-860-001)

 (3)
 Do the operational test of the annunciator light test system (Ref. TASK 33-14-00-710-001).

 


 Subtask 26-13-00-865-050

 B. Make sure that this(these) circuit breaker(s) is(are) closed:
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------121VU APU/FIRE AND OVHT/DET/LOOP B 2WG L44 121VU APU/FIRE AND OVHT/DET/LOOP A 1WG L43 121VU APU/FIRE/EXTIG/SQUIB/B 2WF L39 121VU APU/FIRE/EXTIG/SQUIB/A 1WF L38 121VU APU/FIRE/LP VALVE/NORM 4WF M42 121VU APU/FIRE/LP VALVE/STBY 3WF M41
 4. Procedure
_________
 Subtask 26-13-00-865-051
 A. Open, safety and tag this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU APU/AUTO/EXTIG/GND/TEST  30WF L40
 Subtask 26-13-00-710-050
 B. Do this test:
 -Make sure that the circuit breaker APU AUTO EXTIG GND TEST 30WF (L40) on the panel 121VU is open.
 NOTE : This is necessary to prevent an unwanted automatic fire
____ extinguisher discharge during the test (see TFU REF 26.22.00.007).
 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
1.
 On the circuit breaker panel 121VU: - open the circuit breaker APU

 AUTO EXTIG GND TEST 30WF (L40).

 2.
 On the panel 25VU:  On the panel 25VU:


 -push the APU MASTER SW to ON.  - the blue ON light in the APU MASTER SW comes on.


 -------------------------------------------------------------------------------ACTION RESULT -------------------------------------------------------------------------------
3. On the ENG/APU FIRE panel (1WD) on 20VU:
-push and hold the APU FIRE/TEST pushbutton switch.
-release the APU FIRE/TEST
pushbutton switch.

 4. On the panel 25VU:
-push to release the APU MASTER SW to OFF.
5. On the circuit breaker panel 121VU:
 -close the circuit breaker APU AUTO EXTIG GND TEST 30WF (L40).
 Subtask 26-13-00-865-052On the ENG/APU FIRE panel (1WD) on20VU:- on the APU FIRE pushbutton switch the
APU FIRE light comes on. - on the AGENT pushbutton switch the SQUIB and DISCH lights comes on.
 On the glareshield panels 130VU and 131VU:
 -
the MASTER WARN lights flash.

 -
the continuous repetitive chime is heard.


 On the ECAM upper display unit:
 -
APU FIRE

 -
APU FIRE P/B....PUSH


 -MASTER SW....OFF come on.
All warnings given above are cancelled.
On the panel 25VU:
-the blue ON light in the APU MASTERSW goes off.
 C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
 -------------------------------------------------------------------------------PANEL DESIGNATION IDENT. LOCATION -------------------------------------------------------------------------------
121VU APU/AUTO/EXTIG/GND/TEST 30WF L40

 5. Close-up
________

 Subtask 26-13-00-860-051
 A. Put the aircraft back to its initial configuration.
 (1)
 On the ECAM control panel set the Control/Brightness knobs to OFF.

 (2)
 De-energize the annunciator light test and dimming system (Ref. TASK 33-14-00-710-001).

 (3)
 De-energize the aircraft electrical circuits
 (Ref. TASK 24-41-00-862-002).

 

 

 DETECTOR - APU FIRE (LOOP A AND B) (21WG,22WG) - REMOVAL/INSTALLATION
_____________________________________________________________________
 TASK 26-13-15-000-001 Removal of the Sensing Elements 21WG and 22WG
 1.
 Reason for the Job

__________________
 Self Explanatory


 2.
 Job Set-up Information


______________________
 A. Fixtures, Tools, Test and Support Equipment
 -------------------------------------------------------------------------------REFERENCE QTY DESIGNATION -------------------------------------------------------------------------------
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:A320飞机维护手册 AMM FIRE PROTECTION 防火1(54)