R 1EFF : 004-049, 051-099, 101-149, 151-199, 1 26-16-00Page 19 1201-299, 301-399, 401-499, 1Aug 01/05 1 1 1CES 1
Cargo Compartment Smoke-Detection - Schematic
Figure 005
R 1EFF : 001-003, 1 26-16-00Page 20 1 1 Aug 01/05 1 1 1CES 1
Cargo Compartment Smoke-Detection - Schematic
Figure 005A
R 1EFF : 004-049, 051-099, 101-105, 151-199, 1 26-16-00Page 21 1201-299, 1Aug 01/05 1 1 1CES 1
R **ON A/C 106-149, 301-399, 401-499,
R (Ref. Fig. 005B)
R **ON A/C 004-049, 051-099, 101-149, 151-199, 201-299, 401-499,
R (Ref. Fig. 006A)
R **ON A/C 301-399,
R (Ref. Fig. 006B)
R **ON A/C 004-049, 051-099, 101-149, 151-199, 201-299, 301-399, 401-499,
R A. Normal Operation
R Smoke detected in the cargo compartment will cause:
R - the related SMOKE warning light to come on,
R - the red light in the MASTER WARNING pushbutton switch to flash,
R - the aural repetitive chime to sound,
R - the ECAM upper display unit to show the messages:
R SMOKE FWD/AFT CARGO SMOKE
R ISOL VALVE (of affected compartment) ... OFF (if not automatically
R closed)
R AGENT ... DISCH .
R In the case of a smoke warning the isolation valves of the
R cargo-compartment ventilation system close automatically. They remain
R closed, independent of the smoke warning signals.
**ON A/C 001-049, 051-099, 101-105, 151-199, 201-299,
B. Operation with one Faulty Smoke Detector
When only one detector sends an alarm, the SDCU checks the second
detector automatically. If this test shows a normal function of the
second detector, the result is no indication in the cockpit. The alarm of
the detector is a false warning. If this test shows an abnormal function
of the second detector, the warning signals come on (Ref. Para. 4.A). The
alarm of the first detector is the correct warning.
R 1EFF : ALL 1 26-16-00Page 22 1 1 Aug 01/05 1 1 1CES 1
Cargo Compartment Smoke-Detection - Schematic
Figure 005B
R 1EFF : 106-149, 301-399, 401-499, 1 26-16-00Page 23 1 1 Aug 01/05 1 1 1CES 1
Schematic
Figure 006
R 1EFF : 001-003, 1 26-16-00 Page 24
1 1 May 01/05
1 1
1CES 1
Schematic Figure 006A
R 1EFF : 004-049, 051-099, 101-149, 151-199, 1201-299, 401-499, 1 1CES 1 111 26-16-00 Page 25 Aug 01/05
Schematic
Figure 006B
R 1EFF : 301-399, 1 26-16-00 Page 26
1 1 Aug 01/05
1 1
1CES 1
R **ON A/C 106-149, 301-399, 401-499,
B. Operation with one Faulty Smoke Detector When only one detector sends an alarm, the CIDS-SDF checks the second detector automatically. If this test shows a normal function of the second detector, there is no indication in the cockpit. The alarm of the first detector is a false warning. If this test shows an abnormal function of the second detector, the warning signals come on (Ref. Para. 4.A). The alarm of the first detector is the correct warning.