 Test failed:

 


 -MASTER CAUT lights come on with single chime
 -
ECAM warning: SMOKE LAV+CRG DET FAULT

 -
ECAM maintenance page: SDCU white indication


R 1EFF : 004-049, 051-099, 101-105, 151-199, 1 26-16-00Page 30 1201-299, 1May 01/05 1 1 1CES 1

 

R **ON A/C 106-149, 301-399, 401-499,

 5. Test
____
 A. Manual Test When you press the (PTT) pushbutton switch for more than 2 s a test of the smoke detectors is initiated. The CIDS-SDF does a test of the smoke detectors automatically. The smoke warning signals and indications come on twice. The system also passes the test, when the lamps come on once, that is in case of a failure of one CIDS-SDF channel. The related SMOKE warning light does not come on, if both smoke detectors, installed in one cavity, do not operate, and the test failed. When the PTT pushbutton is pressed, the isolation valves of the cargo-compartment ventilation-system close and the extraction fan stops (Ref. 21-28-00). When the PTT pushbutton is released and the test stops, the isolation valves open and the extraction fan starts. The information is stored in the Centralized Fault Display System (CFDS).
 B. Smoke Warning Test On ground, SMOKE WARN TESTS can be selected on the SDCU menu of the MCDU. A submenu with SMK DET FWD LDCC TEST and SMK DET AFT LDCC TEST is displayed. A test for the FWD cargo smoke detectors or for the AFT cargo smoke detectors can be selected by the line key. During the test the CIDS-SDF sends a test request to the cargo smoke detectors via the CAN bus. If the relative smoke detectors are operative they transmit a test-alarm information to the CIDS-SDF and the cockpit indications (SMOKE warning light, chime and master warning, ECAM message) come on. The test finishes when all indications are confirmed or when the MCDU line key RETURN is selected. If a cargo ventilation system is installed, the isolation valves are in the open position before the test starts. The valves close when the SMOKE condition is simulated. The valves remain in the close position. After a reset of the ventilation controller the isolation valves open again.
R 1EFF : 106-149, 301-399, 401-499, 1 26-16-00Page 31 1 1 Aug 01/05 1 1 1CES 1


 CARGO COMPARTMENT SMOKE DETECTION - ADJUSTMENT/TEST
___________________________________________________
R TASK 26-16-00-710-001 R Operational Check of Cargo-Compartment Smoke-Detection by PTT R 1. Reason for the Job
__________________ R Refer to the MPD TASK: 261600-03 R 2. Job Set-up Information
______________________
R A. Referenced Information
R -------------------------------------------------------------------------------R REFERENCE DESIGNATION R -------------------------------------------------------------------------------
R 24-41-00-861-002 R R 24-41-00-862-002 R R 31-60-00-860-001 R 31-60-00-860-002
R 3. Job Set-up
__________
R Subtask 26-16-00-860-050 Energize the Aircraft Electrical Circuits from the External Power De-energize the Aircraft Electrical Circuits Supplied from the External Power EIS Start Procedure EIS Stop Procedure
R A. Aircraft Maintenance Configuration
R (1) Energize the aircraft electrical circuits R (Ref. TASK 24-41-00-861-002).
R (2) On the overhead panel 22VU, make sure that the AFT ISOL VALVE R pushbutton switch is on (the OFF light off).
R (3) Do the EIS start procedure (Upper ECAM DU and lower ECAM DU only) R (Ref. TASK 31-60-00-860-001).
R (4) Make sure that the ENGINE/WARNING page shows on the ECAM upper R display unit.


R  Subtask 26-16-00-865-050 
R  B. Make sure that this(these) circuit breaker(s) is(are) closed: 
R  -------------------------------------------------------------------------------
R  PANEL  DESIGNATION  IDENT. LOCATION 
R  -------------------------------------------------------------------------------
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 
R  49VU AIR COND/SDCU/CHAN1  11WQ  C06 
R  **ON A/C 001-049, 051-099, 101-105, 201-299, 
R  49VU COM/CIDS/DIR 1 AND 2/ESS  150RH  G02 
R  **ON A/C 106-149, 301-399, 401-499, 
R  49VU AIR COND/CIDS/SDF/DIR2 ESS  18WH  C06 
R  49VU AIR COND/CIDS/SDF/DIR1 ESS  15WH  C05 
R  **ON A/C 106-149, 401-499, 
R  49VU COM/CIDS/DIR ESS/2  157RH  G02 
R  **ON A/C 106-149, 151-199, 301-399, 401-499, 
R  49VU COM DIR ESS/1  150RH  G01 
R  **ON A/C 151-199, 301-399, 
R  49VU COM DIR ESS/2  157RH  G02 
R  **ON A/C 001-049, 051-099, 101-105, 151-199, 201-299, 
R  121VU COM NAV/CIDS/DIR 1 AND 2/NORM  151RH  M05
 