the Smoke Detection Control Unit (SDCU).
 Smoke or fire in one of the lavatories causes a detector to signal the SDCU.
 The SDCU sends signals to the Centralized Intercommunication Data System
 (CIDS) and the Flight Warning Computer (FWC). The FWC gives indications on:


 -
the ECAM upper display unit,
 The CIDS gives indications on:


 -
the FWD attendant panel,

 -
the area call panel.

 

R **ON A/C 106-149, 301-399, 401-499,
 1. General
_______ (Ref. Fig. 001A) A smoke detection system is installed to detect smoke and/or fire in the lavatories. The lavatory smoke detectors are connected to the related DEU B via a CAN bus. The DEU B transmits the information to both CIDS channels. If smoke is detected, the system gives a visual and aural warning to the flight crew. This system is made-up of: - one smoke detector for each lavatory,
 -a DEU B
 -
the CIDS director (Cabin Intercommunication Data System), containing also

 the CIDS-SDF (CIDS Smoke Detection Function) Smoke or fire in one of the lavatories causes a detector to signal this alarm condition to the CIDS director. This alarm condition is then forwarded to the CIDS-SDF which provides the information to the Flight Warning computer (FWC) The FWC gives indications on:

 -
the ECAM upper display unit
 The CIDS gives indications on:


 -
the flight attendant panel

 -
the area call panel

 -
the attendant indication panel

 


 Lavatory Smoke Detection
 Figure 001

R 1EFF : 001-049, 051-099, 101-105, 151-199, 1 26-17-00Page 2 1201-299, 1May 01/05 1 1 1CES 1


 INTENTIONALLY BLANK

 1 1


26-17-00Page 3
1 1 Feb 01/98 1 1 1CES 1


 Lavatory Smoke Detection
 Figure 001A

R 1EFF : 106-149, 301-399, 401-499, 1 26-17-00Page 4 1 1 Aug 01/05 1 1 1CES 1 **ON A/C 001-049, 051-099, 101-105,


 2. Component Location
__________________
R **ON A/C 106-149, 301-399, 401-499,
 2. Component Location
__________________
 **ON A/C 151-199, 201-299,
 2. Component Location
__________________

R **ON A/C 001-049, 051-099, 101-105,
R -------------------------------------------------------------------------------R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA R | | | | DOOR | REF. R -------------------------------------------------------------------------------R 1WQ DET-SMOKE, LAVATORY A 221 831 26-17-00 R 4WQ DET-SMOKE, LAVATORY D 261 831 26-17-00 R 5WQ DET-SMOKE, LAVATORY E 262 831 26-17-00 R 10WQ SDCU 122 811 26-17-34

R **ON A/C 106-149,
R -------------------------------------------------------------------------------R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA R | | | | DOOR | REF. R -------------------------------------------------------------------------------R 1WQ DET-SMOKE, LAVATORY A 221 26-17-15 R 4WQ DET-SMOKE, LAVATORY D 261 26-17-15 R 5WQ DET-SMOKE, LAVATORY E 262 26-17-15 R 8WQ SMOKE DET. DUCT LAV."H" FWD 230 26-17-15 R 10WQ SDCU 122 811 26-17-34R **ON A/C 151-199, 201-299,

 

R -------------------------------------------------------------------------------R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA R | | | | DOOR | REF. R -------------------------------------------------------------------------------R 1WQ DET-SMOKE LAVATORY A 221 831 26-17-00 R 4WQ DET-SMOKE LAVATORY D 261 841 26-17-00 R 5WQ DET-SMOKE LAVATORY E 262 842 26-17-00 R 10WQ SDCU 122 811 26-17-34

R **ON A/C 301-399,
R -------------------------------------------------------------------------------R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA R | | | | DOOR | REF. R -------------------------------------------------------------------------------R 1WQ DET-SMOKE, LAVATORY A 221 26-17-15 R 4WQ DET-SMOKE, LAVATORY D 261 26-17-15 R 5WQ DET-SMOKE, LAVATORY E 262 26-17-15 R 14WQ SMOKE DET. DUCT LAV."L" 251 26-17-15

R **ON A/C 401-499,
R -------------------------------------------------------------------------------R FIN | FUNCTIONAL DESIGNATION | PANEL|ZONE|ACCESS | ATA R | | | | DOOR | REF. R -------------------------------------------------------------------------------R 1WQ DET-SMOKE, LAVATORY A 221 26-17-00 R 4WQ DET-SMOKE, LAVATORY D 261 26-17-00 R 5WQ DET-SMOKE, LAVATORY E 262 26-17-00
R 1EFF : 151-199, 201-299, 301-399, 401-499, 1 26-17-00Page 6 1 1 Aug 01/05 1 1 1CES 1 **ON A/C 001-049, 051-061, 101-105, 201-203,


 3. Description
___________
 A. Smoke Detectors (Ref. Fig. 002) The smoke detectors ionize the air particles that pass between their electrodes. As smoke has a higher specific gravity than air, it causes the electrical resistance of the circuit to increase. The current decreases and the voltage in the measurement chamber increases to a higher level than the reference chamber. At a set difference level the detector sends a signal. The reference chamber makes allowances for differential pressure. It makes sure that the detector operates on the ground and in flight within the same level of sensitivity.
 