 71-00-30
 ALL  ú ú N01 Page 205 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / PW4000 SERIES /747-400 / ENGINES/MAINTENANCE MANUAL ////////////////////////
S 412-077-N00
 (18)
 Close the fan cowl panels (AMM 71-11-04/201).

 S 042-015-N00

 (19)
 Do the activation procedure for the thrust reversers (AMM 78-31-00/201).


 S 862-029-N00
 CAUTION: SUPPLY BOOST PUMP PRESSURE TO THE FUEL PUMP INLET WHEN YOU
_______ FERRY THE ENGINE WITH THE N2 ROTOR FREE TO TURN. THE FUEL PUMP IS LUBRICATED WITH THE FUEL. DAMAGE TO THE FUEL PUMP CAN OCCUR IF YOU DO NOT SUPPLY BOOST PUMP PRESSURE.
 (20) Supply boost pump pressure to the fuel pump inlet.
 (a)  
Make sure the FUEL CONTROL switch is in the CUTOFF position.

 (b)  
On the pilots' overhead panel, P5, make sure that the applicable MAIN AFT and FWD switches for the fuel are in the ON position.

 (c)  
For the applicable engine, open these circuit breakers and install the circuit breaker collars: 1) P6 Main Power Distribution Panel

 a) 6L10 FUEL CONT VALVE ENG 1
 b) 6L11 FUEL CONT VALVE ENG 2
 c) 6L12 FUEL CONT VALVE ENG 3
 d) 6L13 FUEL CONT VALVE ENG 4


 (d)  
Put the FUEL CONTROL switch to the RUN position.

 (e)  
Make sure that the ENG 1, 2, 3, or 4 FUEL VLV display shows on the EICAS.

 (f)  
For the applicable engine, open these circuit breakers and install the DO-NOT-CLOSE tags: 1) P6 Main Power Distribution Panel


 a) 6G1 FUEL SHUTOFF VALVE ENG 1
 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 71-00-30
 ALL  ú ú N01 Page 206 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
b) 6G2 FUEL SHUTOFF VALVE ENG 2 c) 6G3 FUEL SHUTOFF VALVE ENG 3 d) 6G4 FUEL SHUTOFF VALVE ENG 4
 (g)  
Put the FUEL CONTROL switch to the CUTOFF position.

 (h)  
Make sure that the FUEL SPAR VLV 1, 2, 3, or 4 display shows on the EICAS.

 (i)  
Remove the ENG (1, 2, 3, or 4) FUEL VLV EICAS display: 1) Access the CMCS PRESENT LEG FAULTS menu (AMM 45-10-00/201). 2) Find the ENG (1, 2, 3, or 4) FUEL VLV display. 3) Show the display for this fault. 4) Push the line select key adjacent to the ERASE prompt.


 S 212-114-N00
 (21) Do the Spare Engine Inspection.
 (a)  
Supply electrical power (AMM 24-22-00/201).

 (b)  
Do a cycle of these circuit breakers to the open position and then the closed position: 1) P7 Overhead Circuit Breaker Panel

 a) 7C1 FMCS FMC L b) 7C23 FMCS FMC R

 (c)  
Show the PERF INIT page on the CDU: 1) Push the INIT/REF key. 2) Push the line select key (LSK) adjacent to the <INDEX

 prompt to show the INIT/REF INDEX page.

 (d)  
Make sure the line adajcent to the LSK 4R is empty space.


 TASK 71-00-30-572-034-N00
 3.  Prepare to Ferry Engine - Locked Rotor (Fig. 201 thru 204)______________________________________
 A. Special Tools and Equipment
 (1)  
PWA 85985 - Closure, Locking, Pratt & Whiney, Commercial Products Division, 400 Main Street, East Hartford, CT 06108

 (2)  
PWA 26139 - Lock, Gearbox, Pratt & Whitney

 (3)  
PWA 86057 - Fixture, 2.5 Bleed Actuator Retaining, Pratt & Whittney

 (4)  
G57NB-5 - Collars, Circuit Breaker, Nylon Molding Corp., Garwood NJ (four are necessary)


 EFFECTIVITYùùùùùùùùùùùùùùùùùùùùùùùùùùùùùù. ú

 71-00-30
 ALL  ú ú N01 Page 207 ú Jun 18/00
BOEING PROPRIETARY - Copyright (C) - Unpublished Work - See title page for details.
////////////////////////A / PW4000 SERIES /747-400 / ENGINES/MAINTENANCE MANUAL ////////////////////////
B. Standard Tools and Equipment
 (1)  
Coverplate - plywood, 1/4 inch thick, 4.39
 inches (112 mm) in diameter, used
 to cover the end of the start duct


 (2)  
Mats - Protective, Rubber Manufacturers
 
中国航空网 www.aero.cn
航空翻译 www.aviation.cn
本文链接地址:747-400 AMM 飞机维护手册 动力装置 POWER PLANT 2(42)